Permitted Development

Class G flues in a smoke control area

7 min readBy PlanScope Editorial Team

A flue must not exceed the highest part of the roof by 1 metre or more under Class G, and on article 2(3) land it cannot go on an elevation fronting a highway. Smoke control rules are separate.

A flue for a wood burning stove is usually permitted development on a house, and the limit that matters is height: under Class G of Part 1 of Schedule 2 to the General Permitted Development Order 2015, a chimney, flue or soil and vent pipe must not exceed the highest part of the roof by 1 metre or more. Fit a flue that stands a metre or more above the ridge and you have lost the permitted development right for the whole installation rather than for the top section alone.

Permitted development is only half the question. In a smoke control area the appliance and the fuel are controlled separately under clean air legislation, enforced by the council, and a flue that is lawful in planning terms can still leave you with an appliance you cannot lawfully use. Those two systems do not talk to each other.

The height and position limits on a flue

Class G covers the installation, alteration or replacement of a chimney, flue or soil and vent pipe on a dwellinghouse. The height limit is expressed against the highest part of the roof, which on a house with a ridge and a lower rear outrigger means the ridge.

Measure it properly. The highest part of the roof includes any existing chimney stack where the stack is part of the roof structure, and a flue fitted to a rear elevation still measures against the highest part of the roof rather than against the roof slope it emerges from. On a sloping site, the measurement is a vertical dimension between the flue top and the roof, so site levels do not come into it in the way they do for extensions.

Nothing in Class G permits a flue on a building that is not a dwellinghouse. Flats, maisonettes and converted buildings in other uses are outside the class, which is why a flue on a block of flats usually needs an application.

The front elevation restriction on article 2(3) land

On article 2(3) land, which means conservation areas, National Parks, National Landscapes, World Heritage Sites and the Broads, Class G does not permit a flue installed on a wall or roof slope which fronts a highway and forms either the principal elevation or a side elevation of the dwellinghouse.

Three words do the work there.

Term What it means in practice
Fronts a highway Faces a road, footpath or bridleway that is a highway, including a public footpath
Principal elevation The main architectural front, usually but not always the elevation containing the front door
Side elevation A flank wall, which is caught as well as the front where it fronts a highway

So in a conservation area a flue on the rear roof slope is usually fine, and the same flue on the front slope of the same house needs planning permission. Where the house is on a corner plot, both the front and the flank may be caught.

The restriction is about visibility from the street, and officers assess an application for a front flue on exactly that basis. A slim matt black twin wall flue on a slate roof is a different proposition from a stainless steel one, and saying so in the application helps.

Smoke control areas and exempt appliances

Most urban England is covered by smoke control areas. Inside one, you may only burn authorised fuels unless the appliance is an exempt appliance approved for burning a specified fuel. In England the rules on emitting smoke in a smoke control area are enforced by the local authority through financial penalties following changes made by the Environment Act 2021, and the sale of the most polluting domestic solid fuels has been restricted since 2021.

What that means for a householder:

  • Check whether the address is in a smoke control area with the council before buying a stove
  • If it is, choose an appliance on the published list of exempt appliances, and note the fuel it is approved for
  • Burn only the fuel the exemption covers, or an authorised fuel
  • Keep the appliance documentation, because that is what you produce if a complaint is made

An appliance that is exempt is not exempt for every fuel. Several are approved for wood only, and burning smokeless coal in them takes you outside the exemption.

Flues on a listed building

Class G does not displace the need for listed building consent. Installing a flue on a listed building affects its character as a building of special architectural or historic interest, so consent is needed whether or not the work is permitted development in planning terms.

The internal works matter as much as the external flue. Opening up a blocked fireplace, cutting through a historic ceiling or chimney breast, and lining a historic stack are all works affecting the building, and a scheme that only shows the flue outside will be queried.

Expect conservation officers to resist new external flues on principal elevations and to prefer reuse of an existing stack. Where an existing stack can be lined, that is nearly always the route of least resistance.

Conservation area and the principal elevation

Identifying the principal elevation is the single most common point of argument on these applications. The front door is the usual indicator, but not always: a Victorian villa turned to face a later road, a farmhouse with a formal front facing a garden, and a converted barn with no obvious front all cause trouble.

Look at the architecture rather than the address. The elevation with the architectural hierarchy, the better detailing and the original principal entrance is usually the principal elevation, and the government's technical guidance for householders sets out the approach.

Where it is still unclear, apply for a lawful development certificate for proposed development rather than building and hoping. A certificate under section 192 of the Town and Country Planning Act 1990 is the only formal way to confirm that works are lawful, and it costs far less than relocating a flue after a complaint. The same logic applies to other Part 1 limits, as the note on front garden paving, permeable surfaces and Class F explains for surfacing works.

Neighbour amenity and plume dispersal

Where an application is needed, the planning issues are appearance and smoke. A flue terminating below the level of a neighbour's upper window, or close to it, puts combustion products where somebody opens a window, and that is a legitimate amenity objection.

Practical answers: terminate the flue above the ridge line where the height limit allows, keep it at least the distances recommended in the combustion appliance guidance from openings and boundaries, and locate it away from neighbouring windows rather than at the nearest convenient point to the stove.

Illustrative example. A terraced house in a conservation area, stove installed against a party wall, flue proposed on the rear slope 400 millimetres from the boundary and terminating 600 millimetres below the neighbour's bedroom window. Moving the stove to the chimney breast and lining the existing stack removed both the planning issue and the amenity objection, at a lower cost than the external flue. Figures are illustrative.

Building Regulations running alongside

Approved Document J governs the installation: hearth construction, flue size and material, clearances to combustibles, air supply for combustion, flue outlet positions, and a carbon monoxide alarm. Compliance is confirmed either through building control or by a registered competent person scheme installer.

Three points householders miss. A flue that satisfies Class G can still fail the outlet position requirements in the guidance, because the two sets of rules measure different things. Air supply for a stove above a stated output needs a permanent vent, which affects the room. And the installation certificate is what a buyer's solicitor asks for, so keep it.

Where any of this has to be explained to a case officer, a short Planning Statement describing the appliance, the flue specification, the termination height and the distances to neighbouring openings answers the questions before they are asked. For other Part 1 limits that catch householders, the note on the 50 per cent curtilage rule for garden outbuildings is a useful comparison.

This is general guidance, not legal advice; check the position with your local planning authority or a qualified professional before relying on it. PlanScope provides AI-assisted draft reports for planning applications. Reports should be reviewed before submission. We do not guarantee planning approval.

Frequently asked questions

How high can a stove flue be under permitted development?

Class G of Part 1 does not permit a chimney, flue or soil and vent pipe that would exceed the highest part of the roof by 1 metre or more. The measurement is against the highest part of the roof, not the slope the flue emerges from, so a rear flue is still measured against the ridge.

Can I put a flue on the front of a house in a conservation area?

Not under Class G. On article 2(3) land the right does not permit a flue on a wall or roof slope which fronts a highway and forms the principal elevation or a side elevation. A planning application is needed, and it will be judged on how visible and how slim the flue is.

Does a smoke control area stop me installing a stove?

No, but it controls what you can burn. Inside a smoke control area you may burn only authorised fuels unless the appliance is on the published list of exempt appliances, and then only the fuel the exemption covers. Enforcement in England is by local authority financial penalties following the Environment Act 2021.

Do I need listed building consent for a flue?

Yes, where the building is listed. Permitted development rights do not displace listed building consent, and the internal works matter as much as the external flue: opening a blocked fireplace, cutting through a chimney breast or lining a historic stack all affect the building. Reusing an existing stack is usually preferred.

What do the Building Regulations add?

Approved Document J governs hearth construction, flue size and material, clearances to combustibles, combustion air supply, flue outlet positions and a carbon monoxide alarm. A flue can satisfy Class G and still fail the outlet position guidance, because the two sets of rules measure different things.

Sources and further reading

class gpermitted developmentwood burnersmoke controllisted buildings

This article is general guidance about the planning system in England and, where stated, the rest of the UK. It is not legal or professional advice. Check your local planning authority’s validation requirements and take professional advice for your specific site.

More in Permitted Development

View all →
Permitted Development8 min read

Shipping containers and portable buildings on a site

Physical attachment is only one of three tests, and the least important. When a container or portable cabin becomes operational development, which permitted development rights help, and how to regularise units already in place.

Read article →
Permitted Development7 min read

Caravans, mobile homes and annexes in a garden

Stationing a caravan in a garden is not building work, but independent occupation of it is a material change of use. Where the incidental, ancillary and separate dwelling lines fall, and the site licensing regime behind them.

Read article →
Permitted Development7 min read

Part 20 upward extensions to create new dwellings

Part 20 allows new flats on top of existing buildings by prior approval, within storey and height caps and a construction date condition that rules out much of the stock.

Read article →
Permitted Development7 min read

What article 2(3) land removes from householder rights

Conservation areas, National Parks, National Landscapes, the Broads and World Heritage Sites are article 2(3) land, and Schedule 2 strips out several of the most useful householder rights there.

Read article →
Permitted Development6 min read

Antennas and satellite dishes under Class H size limits

Class H permits satellite dishes within four limits: number, size, height above the roof, and position on designated land. The installations that fail are usually on chimneys or front elevations.

Read article →
Permitted Development7 min read

Flues and chimneys under Class G and the one metre rule

A wood burner flue is permitted development under Class G if it stays under one metre above the highest part of the roof. How the measurement works, and the narrower restriction that applies on designated land.

Read article →