Energy, Sustainability and Carbon

MEES and EPC ratings on a conversion scheme

6 min readBy PlanScope Editorial Team

A conversion can be consented, built and still be hard to let. Where the minimum energy efficiency standard bites, and the design choices that decide the rating.

MEES and EPC ratings decide whether a conversion can be let, not whether it can be built. The minimum energy efficiency standard is a letting restriction under the Energy Efficiency (Private Rented Property) (England and Wales) Regulations 2015, enforced by trading standards rather than by the planning authority, and it operates entirely outside the planning system. That separation is why so many conversion schemes reach practical completion with a rating that makes the building difficult to let.

The fix is to treat the target rating as a design constraint at the same point you fix the layout, because most of the measures that move a rating are hard to retrofit once the consent is granted.

What the standard requires of a landlord

For domestic property, landlords have been unable to grant a new tenancy of a property rated F or G since April 2018, and the restriction has applied to all existing tenancies since April 2020. For non-domestic property the same band E minimum applied to new lettings from April 2018 and to continuing lettings from April 2023.

Enforcement sits with the local weights and measures authority, which can serve a compliance notice and impose a financial penalty, with the amount depending on the length of the breach and the type of property. Penalties are published, which matters for institutional landlords.

The standard bites on the EPC rating, so it is the assessment method that decides compliance, not the physics. A building can be warm, well built and rated F because of the way the assessment treats its heating system.

Where it bites on a conversion

A material change of use creating dwellings triggers Part L requirements under the Building Regulations, and the completed units need new energy performance certificates before they are marketed or let. That is the moment the rating becomes visible, and by then the fabric and the heating system are installed.

Three conversion types repeatedly produce poor ratings. Office to residential schemes with deep plan floorplates, single glazed curtain walling that cannot be replaced for planning or ownership reasons, and electric panel heating chosen to keep capital cost down. Agricultural building conversions with large glazed openings, exposed structures and limited insulation depth. And upper floor flats above shops where the heating system is constrained by the commercial unit below.

Electric heating deserves particular attention. The assessment methodology treats direct electric resistance heating harshly, so a scheme that would comfortably reach band C with a heat pump can land two bands lower with panel heaters, at a similar capital cost per unit.

The planning and listed building interface

Planning control and the standard pull against each other more often than they align.

External wall insulation changes the appearance of a building, which needs planning permission where it alters the external appearance materially and is usually resisted in conservation areas on principal elevations. Window replacement in a listed building needs listed building consent and is frequently refused where original joinery survives. Solar panels, air source heat pump units and flue terminations all carry their own consent questions.

Listed buildings are not automatically exempt from needing an EPC. The exemption for officially protected buildings applies where compliance with minimum energy performance requirements would unacceptably alter their character or appearance, which is a test to be applied to the particular building rather than a blanket rule. In practice many listed buildings do need certificates, and the heritage case for restricting measures should be documented in the heritage statement at application stage, because that document becomes the evidence for a later exemption.

Work the two consents together. A scheme that applies for permission to install secondary glazing, internal insulation to selected walls and a heat pump in a discreet location has a route to compliance. A scheme that secures consent first and asks about the rating afterwards usually does not.

Exemptions and the register

Where compliance is not possible, the regulations provide exemptions which must be registered on the national exemptions register before the landlord relies on them. Registration is not automatic and an unregistered exemption is no defence.

The categories that matter on conversions are the cost based exemptions and the consent based ones. For domestic property the relevant improvements are subject to a capital cost cap, set at £3,500 including VAT. For non-domestic property the test is a seven year payback: a measure is not required where its expected payback exceeds seven years.

Consent exemptions cover the situations described above. Where a local authority has refused listed building consent or planning permission for a measure, or where a tenant or lender has refused consent, that refusal supports an exemption entry provided the evidence is in order.

Most exemptions last five years, after which the position has to be reassessed, and an exemption registered by one landlord does not transfer to a purchaser. Diary the expiry.

Four decisions carry almost all of the outcome, and all four cost less to take before the application than after.

  1. The heating system. A heat pump, a communal low temperature system or a connection to a network will move a rating that panel heaters will not.
  2. Glazing. The specification, the opening sizes and whether replacement or secondary glazing is proposed, all of which are visible in the planning drawings.
  3. Insulation strategy. Internal, external or cavity, and the consequent effect on room sizes, reveals and the pre-redevelopment audit where existing fabric is being retained.
  4. Ventilation and overheating. Mechanical ventilation with heat recovery affects the assessment and interacts with the overheating checks, which is a different calculation again, as set out in TM59 or Part O overheating.

Run an indicative assessment on the proposed specification before submission. It costs a fraction of an energy statement and it tells you whether the scheme lets.

Evidence to keep for letting

Keep the assessment inputs, not just the certificate. That means U-values and their source, the heating system specification and controls, the ventilation strategy, glazing data sheets, photographs of insulation before it is covered, and the assessor's conventions notes.

Assessors working from a finished building with no evidence apply default assumptions, and defaults are pessimistic. A wall that is insulated to a known specification will be assessed as unknown construction if nobody photographed it, and the rating drops accordingly.

Keep the planning and listed building decision notices in the same folder. They are the evidence for any consent based exemption.

Where the standard is heading

Government has consulted on raising the minimum standards for both domestic and non-domestic private rented property above band E, with proposals that would require substantially better ratings over the coming years. Those proposals have been revised more than once and the position should be checked against current guidance before any investment decision, because the dates on which they would take effect have moved.

Design for a target above the current minimum where the scheme allows it. A conversion that scrapes band E today is an asset with a known problem and a fixed timetable attached to it, and the cost of upgrading an occupied building is always higher than the cost of doing the work while the scaffolding is up.

Enter your postcode on PlanScope to see which energy and heritage reports your conversion is likely to need, and draft them before the specification is locked down.

This is general guidance, not legal advice; check the position with your local planning authority or a qualified professional before relying on it. PlanScope provides AI-assisted draft reports for planning applications. Reports should be reviewed before submission. We do not guarantee planning approval.

Frequently asked questions

Is the minimum energy efficiency standard a planning requirement?

No. It is a restriction on letting property under the Energy Efficiency (Private Rented Property) (England and Wales) Regulations 2015, enforced by the local weights and measures authority. Planning and building control do not check it. That is why conversions reach completion with ratings that make the finished units difficult to let.

Are listed buildings exempt from needing an EPC?

Not automatically. The exemption for officially protected buildings applies where compliance with minimum energy performance requirements would unacceptably alter their character or appearance, which has to be assessed for the particular building. Many listed buildings do need certificates, so document the heritage constraints on possible measures at application stage.

What is the cost cap on domestic improvements?

For domestic private rented property the relevant improvements are subject to a capital cost cap of £3,500 including VAT. Where the cost of reaching band E exceeds that, a cost based exemption can be registered with the supporting quotations. For non-domestic property the test is different: a seven year payback on the measure.

How long does a registered exemption last?

Most exemptions run for five years, after which the position must be reassessed. An exemption does not pass to a purchaser, so a buyer has to register their own. Registration on the national exemptions register is required before the landlord relies on the exemption, and an unregistered exemption is no defence to enforcement.

Why do electrically heated conversions rate so poorly?

The assessment methodology treats direct electric resistance heating unfavourably because of the fuel factors and system efficiencies applied. A scheme that would reach a much better band with a heat pump can land two bands lower with panel heaters at a similar capital cost, which is why the heating decision should be taken before the application rather than at fit out.

Sources and further reading

meesepcconversionlandlordsenergy efficiency

This article is general guidance about the planning system in England and, where stated, the rest of the UK. It is not legal or professional advice. Check your local planning authority’s validation requirements and take professional advice for your specific site.

More in Energy, Sustainability and Carbon

View all →
Energy, Sustainability and Carbon7 min read

Grid capacity and a rural renewable scheme

On a constrained network the connection offer tells you what scheme is worth applying for. Treating it as an engineering matter for after permission is how capacity gets wasted.

Read article →
Energy, Sustainability and Carbon7 min read

BREEAM energy credits and the condition that secures them

A condition requiring a certified rating is really a condition requiring the low carbon specification to survive value engineering. How to set it up so it does.

Read article →
Energy, Sustainability and Carbon8 min read

Energy statements for a major refurbishment

A refurbishment energy statement has a real baseline and a constrained set of measures. How to establish both, and how to set up the demolition comparator honestly.

Read article →
Energy, Sustainability and Carbon8 min read

The energy hierarchy applied to a single self-build

One house does not need a major scheme's carbon modelling. What the local validation list actually asks for, and how to answer it in two or three pages.

Read article →
Energy, Sustainability and Carbon6 min read

Renewable energy requirements on employment units

A renewables percentage applied to a shell and core warehouse depends entirely on what it is measured against. How to settle the definition and draft a condition that can be complied with.

Read article →
Energy, Sustainability and Carbon7 min read

Solar panels on a pitched roof: permission and policy

Class A of Part 14 allows roof-mounted solar on a house, including the front slope and in conservation areas, subject to a 0.2 metre projection limit and conditions on appearance.

Read article →