Project Type Guides

Planning permission for a crematorium

7 min readBy PlanScope Editorial Team

Section 5 of the Cremation Act 1902 rules out most urban sites before design begins. That is why these schemes end up in the countryside arguing Green Belt policy.

Crematorium planning permission starts with a statutory rule that has nothing to do with the local plan. Section 5 of the Cremation Act 1902 prevents a crematorium being constructed nearer than 200 yards to a dwelling house, except with the written consent of its owner, lessee and occupier, and nearer than 50 yards to a public highway. Those distances rule out most urban and edge of settlement sites before design begins, which is why crematoria end up in the countryside and why Green Belt policy becomes the central planning argument.

Alongside the planning application sits an environmental permit for the cremators themselves, issued by the local authority, and the two processes have to run together rather than in sequence.

Statutory siting requirements and the regulator

Measure the 1902 Act distances first, from the proposed building rather than the site boundary, and identify every dwelling within the radius. Where a dwelling falls inside it, written consent is needed from the owner, the lessee and the occupier, which can be three different parties. A farmhouse in the same ownership as the site is straightforward. A row of cottages with absent landlords is not.

Cremation itself is regulated under the Cremation (England and Wales) Regulations 2008, which cover the operation of crematoria, record keeping and the appointment of a medical referee. That regime is separate from planning and separate again from the environmental permit, and a planning application that treats all three as one document confuses the consultees.

The use is sui generis. It falls outside the Use Classes Order, so there is no permitted change into or out of it, and the description of development should say what is proposed in plain terms, including the number of cremators, the chapel capacity and any memorial garden.

Emissions, abatement and the environmental permit

Cremators are regulated as a Part B installation under the Environmental Permitting (England and Wales) Regulations 2016, with the permit issued by the local authority rather than the Environment Agency. The permit sets emission limits, stack height and monitoring requirements, and the Secretary of State's process guidance for crematoria is the technical standard applied.

Mercury from dental amalgam is the emission that drives the plant design. Abatement equipment adds height, floor area and a second flue run, and the industry operates a burden sharing arrangement under which operators either abate or contribute. Decide which route the scheme takes before the elevations are drawn, because retrofitting an abatement plant room into a designed building rarely works.

For planning purposes the useful document is an Air Quality Assessment that sets out the stack height, the dispersion modelling assumptions and the predicted concentrations at the nearest sensitive receptors. Councils also ask about visible plume and odour, which are more often the subject of objections than mercury is. Request a screening opinion under the Environmental Impact Assessment Regulations 2017 if there is any doubt about whether the scheme is Schedule 2 development, rather than deciding the point yourself.

Traffic, cortege arrangements and parking

This is where applications are most often refused, and the reason is arithmetic. Services are booked at fixed intervals, commonly 45 minutes to an hour, and each one brings a cortege, a congregation arriving before it and the previous congregation leaving. For twenty minutes either side of every service the access and the car park carry three overlapping flows.

Design for that rather than for an average.

  • A separate entrance and exit, so that an arriving cortege never meets a departing one.
  • A holding area inside the site where a cortege can wait off the highway.
  • Parking sized for two services overlapping, with the calculation shown.
  • A drop-off point close to the chapel entrance, level and covered.
  • Overflow parking on a bound surface rather than a grass field that fails in February.

Trip rate databases hold little data on crematoria, so evidence usually comes from surveys of comparable facilities. Say which facilities, when they were surveyed and why they are comparable. A Transport Assessment for a scheme of this kind should also address queuing at the site access during the peak, visibility splays on what is often a rural road, and the swept path of a hearse and a limousine rather than a car.

Landscape, memorial gardens and quiet setting

The setting is part of the function. A crematorium needs to feel separated from traffic noise and from overlooking, and that requirement usually argues for a site with existing mature boundary planting and some topographical containment.

Design the memorial garden as landscape rather than as leftover space. Councils look for a clear arrangement of garden of remembrance, scattering areas, memorial walls or plaques, a route from the chapel exit that avoids arriving mourners, and planting that reads well in winter. Where the site is in a National Landscape or a valued countryside setting, a landscape and visual appraisal proportionate to the scheme will be expected, with views from public rights of way assessed.

Lighting deserves early attention. A car park lit to a commercial standard destroys the character the rest of the design is trying to create, and a lighting scheme with warm, low-level, tightly controlled luminaires is both better and easier to approve.

Noise, hours and residential amenity

Crematoria are quiet uses with a few noisy components. Fixed plant, including the abatement equipment and any air handling, is assessed against the measured background level using the standard method for industrial and commercial sound. Amplified music and bells inside the chapel are assessed as an amenity matter. Vehicle movements and car doors during the arrival and departure peaks are what neighbours actually notice.

Propose hours that match the service pattern you intend to operate, including evening services if you want them, because a condition set to standard daytime hours is awkward to vary later. Set out the number of services per day at the outset and expect a condition limiting it.

One point worth conceding openly. Neighbours object to crematoria on grounds that are not material in planning terms, including distaste and a perceived effect on house prices. Addressing the material issues thoroughly and acknowledging the rest respectfully does more for a scheme than ignoring the objections altogether.

Green Belt and countryside location arguments

The 1902 Act distances push these schemes into the countryside, and in the Green Belt a crematorium building is inappropriate development unless it falls within one of the exceptions in the Framework's Green Belt chapter. Most do not. So the case usually rests on very special circumstances, where the harm to the Green Belt by reason of inappropriateness and any other harm is clearly outweighed by other considerations.

What can be weighed on the other side is need, the absence of a suitable alternative site, and the openness of the scheme's design. Show a sequential search of sites across the catchment with the 1902 Act constraint applied, so that the officer can see how few sites survive it. Keep the building low, single storey where possible, and the parking broken up with planting, then quantify the openness effect rather than asserting it.

In a National Landscape or National Park the test is different again, turning on conserving and enhancing landscape character, and major development in those designations faces a further policy hurdle.

Community need evidence and catchment analysis

Need is the argument that carries very special circumstances, so evidence it properly. The Office for National Statistics publishes deaths registered by area, which is the standard basis for estimating demand within a catchment, and the cremation proportion of funerals is published nationally.

Build the analysis in steps. Define the catchment by drive time from the site, then identify the existing crematoria serving that area and their capacity in services per year. Compare demand with capacity and identify the population that currently travels beyond a reasonable time to reach a facility. Where existing operators run extended hours or long booking intervals, that is evidence of pressure, and it should come from published information rather than anecdote.

A Planning Statement should pull the need case, the sequential site search and the very special circumstances argument into one narrative, with the Design and Access Statement explaining how the building and its setting respond. The structure of a need-based case in the countryside is much the same as the one described for traveller site planning applications.

Enter your postcode on PlanScope to see which reports a scheme of this kind is likely to need.

This is general guidance, not legal advice. Check the position with your local planning authority or a qualified professional before relying on it. PlanScope provides AI-assisted draft reports for planning applications. Reports should be reviewed before submission. We do not guarantee planning approval. For specialist technical reports, qualified professional input may be required.

Frequently asked questions

How far must a crematorium be from houses?

Section 5 of the Cremation Act 1902 prevents construction nearer than 200 yards to a dwelling house, except with the written consent of its owner, lessee and occupier, and nearer than 50 yards to a public highway. Measure from the proposed building and identify every dwelling within the radius before committing to a site.

Who issues the environmental permit for a crematorium?

The local authority, because cremators are regulated as a Part B installation under the Environmental Permitting (England and Wales) Regulations 2016 rather than by the Environment Agency. The permit sets emission limits, stack height and monitoring, applying the Secretary of State's process guidance for crematoria as the technical standard.

What use class is a crematorium?

None. It is sui generis, falling outside the Use Classes Order, so there is no permitted change into or out of the use. The description of development should state what is proposed in plain terms, including the number of cremators, the chapel capacity and any memorial garden or garden of remembrance.

How much parking does a crematorium need?

Enough for two services overlapping, with the calculation shown. Services run at fixed intervals, commonly 45 minutes to an hour, so for twenty minutes either side of each one the site carries an arriving cortege, an arriving congregation and a departing congregation at the same time. Design for that rather than an average.

Can a crematorium be built in the Green Belt?

A crematorium building is normally inappropriate development in the Green Belt, so the case usually rests on very special circumstances, where the harm by reason of inappropriateness and any other harm is clearly outweighed by other considerations. Need, the absence of a suitable alternative site and a low, open design are the arguments that carry weight.

How is need for a new crematorium evidenced?

Define the catchment by drive time, use published deaths registered by area as the demand basis, identify existing crematoria serving that area and their annual service capacity, then compare demand with capacity. Extended operating hours or long booking intervals at existing facilities are evidence of pressure where they come from published information.

Sources and further reading

crematoriumsui generisgreen beltenvironmental permittransport assessmentair quality

This article is general guidance about the planning system in England and, where stated, the rest of the UK. It is not legal or professional advice. Check your local planning authority’s validation requirements and take professional advice for your specific site.

More in Project Type Guides

View all →
Project Type Guides7 min read

Planning permission for a zip wire course in woodland

A woodland zip wire course needs full planning permission, and the case turns on ancient woodland status, what the anchors and platforms do to the trees, and whether the access can take visitor traffic.

Read article →
Project Type Guides7 min read

Permission for housing on a car showroom site

A car showroom redevelops on its contamination report. Staging the intrusive investigation around demolition is what determines the programme.

Read article →
Project Type Guides7 min read

Permission for a rooftop extension to a car park

Development above a multi storey car park stands or falls on column and foundation capacity. Get the intrusive structural appraisal done before anything else is commissioned.

Read article →
Project Type Guides6 min read

Permission for a restaurant terrace on the pavement

Removable tables on the public footway need a pavement licence. A terrace on your own forecourt is a planning matter. Most disputes come down to where the highway edge sits.

Read article →
Project Type Guides7 min read

Permission for new gates and railings to a listed house

Boundary structures at a listed house are usually part of the listing, and permitted development rights for means of enclosure do not apply within the curtilage. Both consents are needed.

Read article →
Project Type Guides7 min read

Permission for a basement cinema under a listed house

A basement under a listed building needs listed building consent, a structural method statement and usually a basement impact assessment. The statutory duty on harm decides most of these cases.

Read article →