Flood, Drainage and SuDS

Sequential Test: agreeing the area of search

6 min readBy PlanScope Editorial Team

The area of search decides the outcome of a sequential test more often than the flood zone does. Define it from the development's function, and evidence every discount from the council's own list.

The area of search decides the outcome of a flood risk sequential test more often than the flood zone does. Draw it too wide and you inherit dozens of sites you have to discount one by one. Draw it too narrowly and the officer rejects the test as self-serving, usually in the last fortnight of the determination period.

The default is the local planning authority's administrative area. Departing from that default is possible, and sometimes correct, but it has to be argued from the development's function rather than from convenience.

Why the geography decides the result

The sequential test asks whether there are reasonably available sites appropriate for the proposed development in areas at lower risk of flooding. If there are, permission should be refused. The test is comparative, so the comparison set is the whole argument.

Since the December 2023 revision, the test applies to all sources of flood risk rather than river and sea flooding alone. Surface water, groundwater, reservoirs and sewer flooding all count. That change widened the number of sites that fail and it also widened the evidence you need about the alternatives, because a candidate site in Flood Zone 1 with a surface water flow path across it is not automatically at lower risk.

Officers who reject a sequential test almost always reject it for one of three reasons: the search area was too small, the discount reasons were unsupported, or the test ignored sites the council's own evidence base identifies. The first is the one applicants control least well.

Setting the geography against the need

Start from what the development is actually for, then define the smallest area that meets that need honestly.

Development Usual area of search Why
Open market housing The whole LPA area The need is not tied to a location
Affordable housing for a parish The parish or a defined rural area The need arises locally and is evidenced by a housing needs survey
Replacement school The school's catchment The function is fixed by the pupils it serves
Extension to an existing business The existing site and its immediate surroundings Relocation would defeat the purpose
Sub-regional employment site The housing market area or functional economic area The need is evidenced at that geography

The reasoning has to be published somewhere the council accepts. A housing needs survey, an adopted local plan policy that identifies a settlement hierarchy, an economic needs assessment, or a school place planning report all do the job. An assertion by the applicant does not.

Where you are arguing for a smaller area, expect the council to test it. The question they ask is whether the need could be met somewhere else without material disadvantage, and a good answer names the disadvantage rather than asserting one.

What makes a site reasonably available

Available means available now, or within a timescale that meets the need. A site with an extant permission for something else, a site in an unwilling owner's hands, and a site that is physically constrained by ownership severance are all arguable discounts, provided you evidence them.

The Planning Practice Guidance on flood risk and coastal change points to the council's own evidence base as the starting point. In practice that means the strategic housing and economic land availability assessment, the brownfield land register, the local plan allocations and any call for sites responses that the council has published. Use those lists rather than compiling your own, because compiling your own invites the response that you left something out.

Suitability is separate from availability. A site large enough in principle may be unsuitable because it is allocated for another use, because it lies in the Green Belt, because it carries a heritage designation that would prevent the quantum, or because its own flood risk from a different source is worse. All of those are legitimate discounts when they are evidenced.

Viability is the weakest discount and the one most often challenged. Saying a site is unviable requires the same order of evidence as a viability case in any other context, and a single line in a table will not survive.

Recording the discounts

Build the test as a table with one row per site and four columns: the site reference from the council's own evidence base, its area and capacity, the flood risk position across all sources, and the reason for discount with the evidence relied on.

Do not abbreviate the reasons. "Not available" is not a reason. "Allocated for employment use under policy E3 and subject to a 2024 reserved matters approval for a distribution unit" is a reason, and it can be checked.

Two further disciplines help. Give the date at which the availability position was assessed, because sites move. And include the sites that pass, if any, with an explanation of why the proposal cannot go there. A test that discounts every single alternative on the first pass reads as constructed backwards, and officers notice.

The output belongs in a standalone Sequential Test document cross-referenced from the Flood Risk Assessment rather than buried in an appendix. Officers copy it into the committee report, so make it copyable.

Where the local plan has already applied the test

Where a site was allocated through the plan-making process and the sequential test was applied at that stage, the guidance accepts that it does not normally need to be reapplied for a proposal consistent with the allocation. The practical conditions are that the allocation is current, that the proposal matches what was allocated in use and scale, and that the flood risk evidence has not changed materially since adoption.

That last condition does most of the work now. A plan adopted before the 2023 change to all sources of flood risk may have applied a narrower test, and climate change allowances have been updated since many plans were examined. Check the strategic flood risk assessment that underpinned the allocation and its date before relying on it.

The test is also not required for minor development or for changes of use, with the exception of a change of use to a caravan, camping or chalet site. A site-specific flood risk assessment may still be needed, and the basement flood risk tests apply to below-ground accommodation regardless of the sequential position.

Presenting the test so an officer can adopt it

Case officers are writing a report under time pressure and they need three things from you: a clear statement of the area of search and its justification, a table they can lift, and a conclusion in the language of the policy.

Write the conclusion as a finding, not a plea. Something to the effect that no reasonably available sites appropriate for the development exist in areas at lower risk of flooding within the defined area of search, for the reasons set out in the table. Then deal with what follows. If the proposal is in Flood Zone 2 or 3 and the vulnerability classification requires it, the Exception Test comes next and needs both limbs answered.

Send the draft to the case officer before you submit if the relationship allows it. Agreeing the area of search in advance costs one email and saves a refusal. The lead local flood authority will separately scrutinise the surface water case, and understanding what it checks in a drainage strategy helps keep the two consultations aligned.

This is general guidance rather than legal advice. Check the position with your local planning authority or a qualified professional before relying on it, and verify the current National Planning Policy Framework policy references on gov.uk, because the Framework moved to policy codes in the edition published on 17 August 2026. PlanScope provides AI-assisted draft reports for planning applications. Reports should be reviewed before submission. We do not guarantee planning approval.

Frequently asked questions

What is the default area of search for a sequential test?

The local planning authority's administrative area is the normal starting point for open market development. A narrower area can be justified where the need itself is local, such as rural affordable housing supported by a parish housing needs survey, or where the function is fixed, such as a school serving a defined catchment.

Does the sequential test cover surface water flooding?

Yes. Since the December 2023 revision to national policy the test applies to all sources of flood risk, including surface water, groundwater, reservoirs and sewers, rather than river and sea flooding alone. A candidate alternative site in Flood Zone 1 with a surface water flow path across it is not automatically at lower risk.

When is a sequential test not required?

It is not normally required for minor development or for changes of use, other than a change of use to a caravan, camping or chalet site. It is also not usually reapplied where a site was allocated through plan making and the test was applied then, provided the proposal matches the allocation and the evidence has not changed.

Can I discount an alternative site on viability grounds?

You can, but it is the weakest discount and the most often challenged. Viability discounts need the same order of evidence as a viability case in any other planning context, with inputs an officer can test. A single line in a table asserting that a site is unviable will not survive scrutiny at committee or on appeal.

Who agrees the area of search?

The local planning authority decides, as the body applying the test. The Environment Agency is consulted on proposals in Flood Zones 2 and 3 but does not apply the sequential test itself. Agreeing the geography with the case officer before submission is worth the email, because a rejected search area usually means a refusal.

Sources and further reading

flood risksequential testplanning policydrainageconsultant

This article is general guidance about the planning system in England and, where stated, the rest of the UK. It is not legal or professional advice. Check your local planning authority’s validation requirements and take professional advice for your specific site.

More in Flood, Drainage and SuDS

View all →
Flood, Drainage and SuDS8 min read

Blue roofs in the drainage calculation

The hydraulics of roof attenuation are straightforward; getting the volume credited is not. This covers storage depth against structural loading, flow control modelling, failure modes and the drawings reviewers expect.

Read article →
Flood, Drainage and SuDS7 min read

Choosing between the central and upper end climate allowance

The Environment Agency publishes bands rather than a single climate uplift. This explains how vulnerability classification, flood zone and catchment select the allowance, and how to document the choice so a reviewer can check it.

Read article →
Flood, Drainage and SuDS8 min read

Local resilience forums and flood emergency planning

Flood emergency planning sits with local resilience forums under the Civil Contingencies Act, not with the planning system. Here is how the two meet.

Read article →
Flood, Drainage and SuDS8 min read

Sewerage design standards and sewer adoption approval

Adoptable sewers are designed to the sewerage undertaker's standards, not the council's. Here is what governs the layout, how the application runs and where the programme slips.

Read article →
Flood, Drainage and SuDS6 min read

Flood Re and what buyers will ask about

Homes built on or after 1 January 2009 cannot use Flood Re, so new build insurance rests on the open market. What to hand over at completion and what not to promise.

Read article →
Flood, Drainage and SuDS7 min read

Trash screens and the liability they create

Screens protect a culvert and introduce a new flood risk upstream. How blockage is modelled, which designs degrade gracefully, and who maintains the structure afterwards.

Read article →