Solar thermal against photovoltaic in an energy strategy

7 min readBy PlanScope Editorial Team

Solar thermal only offsets hot water, which is modest and seasonally mismatched in modern dwellings. The exception is buildings with large, steady hot water loads, and that is the case worth arguing properly.

On most housing schemes photovoltaic panels now beat solar thermal collectors in an energy strategy, and the reason is arithmetic rather than fashion. Solar thermal only offsets hot water demand, which in a well insulated dwelling is modest and seasonally mismatched with the resource. Photovoltaics offset electricity, which every building uses year round, and the carbon factors used in current compliance calculations reward generating electricity far more than they reward displacing gas.

That is the general answer. It reverses on buildings with large, steady hot water loads, and getting the exception right is worth more than repeating the rule.

What each technology contributes

A solar thermal collector, whether flat plate or evacuated tube, heats a fluid that transfers heat to a twin-coil cylinder. It reduces the energy needed for domestic hot water and does nothing else.

A photovoltaic array generates electricity. That electricity offsets whatever the building is using at the time, including lighting, small power, ventilation, a heat pump, and hot water where a diverter sends surplus generation to an immersion heater.

The difference matters most in a modern dwelling. Fabric standards have cut space heating demand, so hot water is a larger share of a smaller total, but the absolute hot water load in a two or three person household is still limited. A collector sized to meet a meaningful share of it spends the summer producing heat nobody needs and the winter producing little.

Add to that the carbon accounting. The decarbonisation of grid electricity assumed in the current calculation methodology reduced the carbon value of measures that displace gas and increased the value of measures that generate electricity. A technology that saves a kilowatt hour of gas is worth considerably less in the compliance run than one that generates a kilowatt hour of electricity.

Hot water demand profiles and seasonal match

The case for solar thermal turns on the demand profile, so start there rather than with the technology.

Solar thermal performs well where hot water demand is high, consistent across the year, and spread through the day rather than concentrated in two peaks. Buildings with that profile include hotels, care homes, student accommodation with communal facilities, gyms and leisure centres, and industrial processes with a hot water requirement.

It performs badly where demand is low, peaks in the morning and evening, and falls away in summer when occupants are absent. That describes most family housing.

Storage bridges some of the gap and not all of it. A larger cylinder captures more of the midday resource, and it also increases standing losses and takes floor area that in a flat is expensive. On a scheme of compact apartments, the cylinder is often the binding constraint rather than the collector.

Roof area and what else wants it

Roof area is the scarcest resource on most urban schemes and the competition for it is real: plant and risers, lift overruns, photovoltaics, solar thermal, green or biodiverse roof required by policy, amenity terraces, rooflights, and maintenance access with edge protection.

Allocate it explicitly in the strategy rather than showing a hopeful array on a roof plan. Draw the plant zone, the access routes, the fall protection zone and the biodiverse roof first, then see what is left and at what orientation.

Orientation and pitch affect the two technologies differently. Photovoltaic output falls away gently across a wide range of orientations, which is why east-west arrays on flat roofs are now common. Solar thermal is more sensitive, because a collector that underperforms in spring and autumn loses the shoulder-season contribution that made the case in the first place.

Overshadowing is worth a specific check. A single lift overrun or a neighbouring building can take a disproportionate share of output from a small array, and the assessment should show it rather than assume an unobstructed roof.

Interaction with a heat pump or a heat network

Where the dwelling has a heat pump, the marginal value of solar thermal falls sharply. The heat pump already produces hot water at an efficiency well above unity, so the collector is displacing energy that was already low in carbon terms. Photovoltaics, by contrast, complement a heat pump directly by offsetting the electricity it consumes.

Where the scheme connects to a heat network, individual dwellings usually have no heat generating plant at all, so solar thermal has nothing to integrate with and the network operator will resist anything that reduces heat offtake. Photovoltaics remain available and are usually the only on-site generation in the strategy. The consenting and policy questions around connection are covered in heat network zoning and what it means for a planning application.

There is one honest complication. On a communal hot water system serving a block, solar thermal into a central plant room can work where a single dwelling could not, because the aggregated demand is steadier. If the building type suits it, model it properly rather than dismissing it.

Maintenance and the long view

Photovoltaic arrays have no moving parts and a long design life, with inverter replacement the main intervention. Cleaning is occasional and output degrades slowly and predictably.

Solar thermal systems have a pumped circuit, a heat transfer fluid that degrades and needs replacing, expansion vessels, and a stagnation condition in summer when the cylinder is satisfied and the collector keeps absorbing heat. That condition is designed for, and it is also the reason these systems need servicing that residential occupiers frequently do not arrange.

A commitment made at planning that depends on a maintenance regime nobody funds is a commitment that lapses. Where a management company will hold responsibility, say so and say what the arrangement is. Where individual leaseholders will, be realistic about it in the report.

How each appears in the compliance calculation

In a dwelling calculation, a photovoltaic array appears as generation reducing the dwelling emission rate, and a solar thermal system appears as a reduction in the energy required for water heating. In a non-domestic calculation the treatment is analogous but the building services inputs are more detailed, and the choice of calculation tool for a mixed scheme carries its own issues, set out in choosing between SAP and SBEM for a mixed-use scheme.

Two points to get right in the submission. Report the same array area, orientation and pitch in the drawings and in the calculation, because a mismatch is the commonest technical query on an Energy Statement. And where the strategy relies on a diverter sending surplus generation to hot water, say whether the calculation has taken credit for it, because the treatment differs between methodologies.

Do not forget overheating. Cylinder and pipework losses from a solar thermal installation add internal gains in summer, which is exactly when the assessment under the relevant standard is least forgiving. Check the interaction with the Overheating Risk Assessment rather than treating the two documents as separate exercises.

Justifying the choice to an officer

Officers rarely have a preference between the technologies. What they want is evidence that the choice was made rather than defaulted to.

  1. State the hot water demand profile for the building type, with the basis for it.
  2. State the usable roof area after plant, access, biodiverse roof and amenity, with a drawing.
  3. Present the carbon saving for each option over the same area, using the same calculation method.
  4. Explain the interaction with the heating system, whether that is a heat pump, a boiler or a network connection.
  5. Set out the maintenance regime and who will carry it.
  6. Show the result against the local plan target where one is set, expressed in the same units the policy uses.

An illustrative example. A scheme of 40 flats with a communal air source heat pump has roughly 280 square metres of usable roof after plant and a policy-required biodiverse roof. The strategy models photovoltaics across the whole area and solar thermal across a third of it with communal storage. Photovoltaics deliver the larger saving, and the report says so with the numbers attached, rather than asserting that panels are the modern choice. That is a two page section, and it settles the question.

This is general guidance, not legal advice. Check the position with your local planning authority or a qualified professional before relying on it.

PlanScope provides AI-assisted draft reports for planning applications. Reports should be reviewed before submission. We do not guarantee planning approval. For specialist technical reports, qualified professional input may be required.

Frequently asked questions

Why do photovoltaics usually outperform solar thermal on housing?

Because solar thermal only offsets hot water demand, which is modest in a well insulated dwelling and peaks in the morning and evening when the resource is weakest. Photovoltaics offset electricity used across the whole day and the whole year. Current carbon factors also reward generating electricity more than displacing gas, which widens the gap in the compliance calculation.

When is solar thermal the better choice?

Where hot water demand is high, steady across the year and spread through the day rather than concentrated in peaks. Hotels, care homes, student accommodation with communal facilities, gyms, leisure centres and processes with a hot water requirement all fit that profile. Communal systems serving a block can also work where an individual dwelling would not, because aggregated demand is steadier.

Does solar thermal make sense with a heat pump?

Rarely. A heat pump already produces hot water at an efficiency well above unity, so the collector displaces energy that was already low in carbon terms. Photovoltaics complement a heat pump directly by offsetting the electricity it consumes. On a heat network connection there is usually no individual heat plant to integrate with at all.

How should roof area be allocated in an energy strategy?

Explicitly and on a drawing. Set out the plant zone, risers, lift overruns, maintenance access and fall protection, any policy-required biodiverse roof and amenity terraces first, then show what remains and at what orientation. Include overshadowing from lift overruns and neighbouring buildings rather than assuming an unobstructed roof.

What do officers want to see in the comparison?

Evidence that the choice was made rather than defaulted to. State the hot water demand profile and its basis, the usable roof area after other demands, the carbon saving for each option over the same area using the same method, the interaction with the heating system, the maintenance regime, and the result against any local plan target in the units the policy uses.

Sources and further reading

solar thermalphotovoltaicsenergy statementpart lheat pumpsroof area

This article is general guidance about the planning system in England and, where stated, the rest of the UK. It is not legal or professional advice. Check your local planning authority’s validation requirements and take professional advice for your specific site.

More in Energy, Sustainability and Carbon

View all →
Energy, Sustainability and Carbon6 min read

Embodied carbon of foundations and ground works

On brownfield sites the substructure can carry more embodied carbon than the frame above. How piling, rafts, ground improvement and mix design compare, and how to report substructure so the saving is reviewable.

Read article →
Energy, Sustainability and Carbon7 min read

Green roofs: what counts and what the drawings must show

A thin sedum blanket satisfies almost no current policy. What separates extensive, biodiverse and intensive roofs, how much attenuation credit to expect, and the drawings that discharge the condition.

Read article →
Energy, Sustainability and Carbon6 min read

Water efficiency standards and how to hit 110 litres

The tighter 110 litre standard applies only where a plan policy adopts it and a condition imposes it. How the water efficiency calculation works and which fittings decide the result.

Read article →
Energy, Sustainability and Carbon7 min read

Energy and carbon conditions: what gets discharged when

Energy and carbon conditions bite at different points in the programme. The triggers, the as-built evidence councils accept, and what to do when design changes break one.

Read article →
Energy, Sustainability and Carbon7 min read

Overheating risk in a loft conversion

Sloping rooflights collect more solar gain than vertical windows, and a converted loft has almost no thermal mass. Part O rarely applies, so the design has to deal with it.

Read article →
Energy, Sustainability and Carbon7 min read

Electricity grid capacity and when it stops a scheme

Capacity is a deliverability problem, not a policy objection. What to ask the network operator, how to read an offer, and how phasing conditions should be drafted.

Read article →