The declaration that accompanies a telecommunications prior approval application is a one-page document, and it is the only part of the submission that touches public health. It states that the installation is designed to be in full compliance with the public exposure guidelines of the International Commission on Non-Ionizing Radiation Protection. The question developers and site providers keep asking is who is entitled to sign it.

The short answer is the code operator, or someone authorised to act on the operator's behalf, on the basis of radio frequency engineering work carried out to the operator's standard. The signature is an operator liability, not a consultant's opinion offered at arm's length.

What the declaration certifies

Part 16 of Schedule 2 to the General Permitted Development Order 2015 governs development by electronic communications code operators, and prior approval applications for the siting and appearance of installations must be accompanied by a declaration of conformity with the ICNIRP public exposure guidelines.

Read carefully, the declaration is about design rather than measurement. It certifies that the installation as designed, with the equipment specified and the power levels and antenna patterns assumed, will keep public exposure within the guideline levels. It does not certify post-installation measurements, and it is not a certificate of ongoing compliance.

That distinction matters when objections arrive. A declaration cannot be contradicted by pointing at a different site, and it can only be tested by engaging with the design assumptions: equipment type, effective radiated power, antenna height and downtilt, and the location of any accessible area within the compliance boundary.

The current guidelines are the ICNIRP 2020 guidelines for limiting exposure to electromagnetic fields in the 100 kHz to 300 GHz range, which replaced the 1998 guidelines for that frequency range. A declaration citing the 1998 guidelines without explanation is a reason to ask a question.

Radio frequency engineering competence

There is no statutory register of radio frequency engineers and no protected title, so competence is demonstrated rather than certified. What a case officer or a reviewer should look for is a named individual with specific experience in electromagnetic field exposure assessment, working to a documented method, with chartered status in electrical or electronic engineering as the usual professional backstop.

The underlying work is a compliance assessment: calculating exposure levels around the antennas, establishing the compliance boundary within which public access must be restricted, and confirming that the boundary falls inside the operator's controlled area rather than across a footway, a balcony or a rooftop used by maintenance staff.

Competence questions are the same ones that arise for other specialist disciplines where the planning system relies on a declaration rather than a licence. The approach set out in our note on acoustician qualifications in planning transfers directly: look for the individual, the method and the professional body, in that order.

Operator responsibility and the signatory

The operator holds the Ofcom wireless telegraphy licence, and licence conditions require compliance with the ICNIRP general public exposure levels. That is the real enforcement route for exposure, and it sits outside the planning system entirely.

In practice the declaration is signed by an authorised officer or agent of the operator, relying on internal radio frequency engineering records and the manufacturer's data for the equipment. On shared sites it is signed by the operator making the application, which creates the cumulative question dealt with below.

A planning agent should not sign it. Nor should a site provider, a landlord or a tower company that does not hold the licence and does not control the radio configuration. Where an agent submits the application, the declaration should still be executed by or for the operator and included as a separate document rather than absorbed into the covering statement.

Where the declaration sits in the application

Three routes exist, and the declaration follows the equipment rather than the route:

Route When it applies Declaration required
Part 16 prior approval Development by a code operator needing approval of siting and appearance Yes, with the application
Permitted development without prior approval Smaller installations within the Part 16 limits Yes, kept on record by the operator
Full planning application Development outside Part 16, or where rights are removed Yes, as a supporting document

On a prior approval application the authority has 56 days to determine, and the matters for consideration are siting and appearance. Health is not among them, because national policy has for many years directed authorities not to set their own health safeguards where a declaration of ICNIRP conformity is provided. Verify the current wording in the Framework published on 17 August 2026 before quoting it, since the chapters were recoded in that edition.

PlanScope drafts a Telecommunications Compliance report that sets out the policy position, the site context and the structure the declaration sits within. Councils usually expect a suitably qualified author for this work, and professional review is strongly advised; the declaration itself must come from the operator.

Challenges to the declaration and their weight

Objections on health grounds are common and rarely succeed. Inspectors have consistently treated a properly executed declaration as answering the exposure question, and have declined to go behind it on the basis of general concern or contested research. Those decisions are indicative of the approach rather than binding precedent.

What does get traction is a challenge to the completeness of the submission. If the declaration is missing, unsigned, undated, made by the wrong party, or refers to a different site or a superseded equipment specification, the application has a problem the authority can act on. The same applies where the compliance boundary plainly overlaps publicly accessible space and nothing in the submission addresses access control.

So the defensive work is clerical as much as technical. Check the site reference, the date, the signatory's authority and the guideline edition before submission. Those four checks remove most of the ground an objector can stand on.

Keeping the record for later sites

Operators and site providers accumulate declarations across hundreds of sites, and the records matter at three later points: a site upgrade that changes the radio configuration, a dispute with an occupier about rooftop access, and a renewal or variation application years later.

Keep the declaration with the radio configuration data it relied on, the equipment datasheets, the compliance boundary drawing and the access control arrangements. A declaration filed alone, without the assumptions behind it, cannot be reused when the equipment changes. The discipline is the same one that applies to lighting evidence, where the guidance edition and the modelled assumptions have to travel with the result, as our note on the guidance councils cite for lighting design sets out.

Record the date of any post-installation audit separately. Audits are not what the planning declaration certifies, and conflating the two creates a gap when someone asks for evidence of as-built compliance.

Appointing for a shared site

Site sharing is normal, and it is where the single-operator declaration gets uncomfortable. Each operator's declaration covers its own installation. Public exposure at a shared mast is the sum of contributions from every operator present.

The way this is handled in practice is a cumulative assessment, prepared for the site as a whole, with each operator's declaration referencing it. When appointing for a shared site, make that explicit in the brief:

  • scope the assessment to all existing and proposed transmitters on the structure, not only the new one
  • require the compliance boundary drawing to show the cumulative result
  • require the assumptions for other operators' equipment to be stated and sourced
  • set out who updates the assessment when any operator changes configuration
  • identify the access control measures and who maintains them

The last point is the one that gets forgotten and the one that causes problems on rooftops, where a maintenance contractor working on plant can end up inside a compliance boundary nobody told them about.

Where a reviewer with the right competence is needed for the planning documents that sit around the declaration, the professional directory is the route to a sign-off. For specialist technical reports, qualified professional input may be required. PlanScope provides AI-assisted draft reports for planning applications. Reports should be reviewed before submission. We do not guarantee planning approval. This is general guidance, not legal advice; check the position with your local planning authority or a qualified professional before relying on it.

Frequently asked questions

Who signs the ICNIRP declaration?

An authorised officer or agent of the electronic communications code operator, relying on internal radio frequency engineering work and manufacturer data. A planning agent, landlord or tower company that does not hold the wireless telegraphy licence and does not control the radio configuration should not sign it, even where the agent submits the application.

What does the declaration actually certify?

That the installation as designed will keep public exposure within the ICNIRP public exposure guidelines, given the specified equipment, power levels and antenna arrangement. It is a design statement rather than a measurement record, and it is not a certificate of ongoing compliance after installation.

Which ICNIRP guidelines apply?

The 2020 guidelines for limiting exposure to electromagnetic fields in the 100 kHz to 300 GHz range, which replaced the 1998 guidelines for that frequency range. A declaration that cites the 1998 guidelines without explaining why is worth querying, because the equipment specification may also be out of date.

Can a council refuse on health grounds?

National policy has long directed authorities not to set health safeguards of their own where a declaration of conformity with ICNIRP guidelines is provided, and the matters for a Part 16 prior approval are siting and appearance. Check the current wording in the Framework published on 17 August 2026, as the chapters were recoded.

How are shared mast sites assessed?

Through a cumulative assessment covering every existing and proposed transmitter on the structure, because public exposure is the sum of all contributions. Each operator's declaration then references that assessment. The brief should state who updates it when any operator changes configuration and who maintains access control.

How long does a Part 16 prior approval take?

The authority has 56 days to determine a prior approval application for the siting and appearance of a code operator installation. A missing, unsigned or misdated declaration is a straightforward reason for the application to be held up, so the clerical checks are worth doing before submission rather than after.

Sources and further reading

telecommunicationspart 16icnirpprior approvalprofessional competencemasts

This article is general guidance about the planning system in England and, where stated, the rest of the UK. It is not legal or professional advice. Check your local planning authority’s validation requirements and take professional advice for your specific site.

More in Professionals and Qualifications

View all →
Professionals and Qualifications6 min read

Who signs a Design and Access Statement

There is no signature block and no prescribed author for a Design and Access Statement. Article 9 of the DMPO 2015 says when one is needed and what it must explain.

Read article →
Professionals and Qualifications6 min read

Checking a consultant's membership and currency

Letters after a name tell you somebody passed an assessment once. Currency, indemnity cover and the right institute are what protect you.

Read article →
Professionals and Qualifications6 min read

Odour assessment competence and who can sign one

An odour risk assessment needs dispersion judgement as well as ductwork knowledge. The two skills rarely sit in the same person, and almost never in the supplier.

Read article →
Professionals and Qualifications7 min read

Transport evidence: who signs a trip generation note

A trip generation note is only as good as the judgement behind the site selection. Here is the competence highway authorities look for and what to put in the brief.

Read article →
Professionals and Qualifications6 min read

Whole life carbon assessment competence and scope

The RICS whole life carbon standard fixes the modules, the 60 year study period, the data rules and the reporting format. Most differences between assessments come from scope choices, not arithmetic.

Read article →
Professionals and Qualifications7 min read

Overheating assessments and CIBSE TM59 competence

Nobody is licensed to run a CIBSE TM59 overheating assessment, so competence is judged on the inputs. The weather file, assumptions schedule and per-room results are the places to look.

Read article →