Which Reports Do I Need

Reports for a crematorium and memorial garden

6 min readBy PlanScope Editorial Team

Two regimes run together: planning permission and an environmental permit that sets the stack height. The statutory siting distances, the traffic peaks around service times and the landscape case.

A crematorium is a sui generis use, so there is no permitted development route and no movement within a use class to rely on. The application is a full one, and the evidence base is unusual because two regimes run side by side: planning permission from the local planning authority and an environmental permit for the cremators from the same council's regulatory side. The permit drives the stack height, and the stack height drives the design.

The other unusual feature is a statutory siting rule that predates modern planning and still bites. Under the Cremation Act 1902 a crematorium may not be built within 200 yards of a dwelling house, except with the consent of the owner, lessee and occupier, nor within 50 yards of a public highway, nor in the consecrated part of a burial ground.

Use class and the siting policy position

Crematoria fall outside the Use Classes Order. That matters in two directions: nothing permits a change into the use, and once established the use cannot drift into something else without permission.

Policy support usually comes from two places. National policy supports the provision of community facilities and services, and the local plan may carry a specific policy or an identified need for additional capacity. Where the site is in the Green Belt, a crematorium is inappropriate development unless it falls within an exception, and the case then has to be built on very special circumstances with the need evidence doing the heavy lifting.

Most sites are on the edge of settlements, which is where the 200 yard rule becomes workable and where landscape and highway issues concentrate. Establish both the statutory distances and the Green Belt or landscape designation position before any design work, because a site that fails the 1902 Act distances cannot be rescued by good design.

Mercury abatement and emissions permitting

Cremators are regulated installations requiring a permit under the Environmental Permitting (England and Wales) Regulations 2016, administered by the local authority rather than the national regulator. Mercury abatement expectations are set in the published process guidance for the sector, and the permit will specify emission limits, monitoring and abatement provision.

Two consequences for the planning application. First, the abatement plant has a physical footprint and a height, and designing the building before the permit discussion produces a plant room that does not fit. Second, the authority's regulatory officers and its planning officers are different teams, and getting them in the same pre-application meeting saves a round of revisions.

Say clearly in the planning submission that emissions are controlled through the permit regime, and that the planning assessment addresses the physical and amenity consequences rather than duplicating the permit. Authorities accept that division when it is explained.

Air quality and the stack height case

Stack height is determined by dispersion modelling rather than by architectural preference, and the modelling has to account for building downwash from the crematorium itself and from nearby structures.

An Air Quality Assessment should set out the modelled scenario, the receptors considered, the assumed emission rates and the resulting stack height, then show how that height has been accommodated in the design. Councils usually expect a suitably qualified author for this work and professional review is strongly advised.

The design tension is obvious and worth confronting in the design statement rather than hiding. A stack tall enough to disperse properly is a vertical element in a sensitive landscape. The answers are integration into the building mass, careful material selection and honest visualisations, not a shorter stack.

Traffic arrival patterns around service times

Crematorium traffic is unlike almost any other use. Arrivals and departures cluster tightly around scheduled service times, with a cortege arriving as the previous congregation leaves, which produces short, intense peaks separated by quiet periods.

A Transport Assessment for a crematorium therefore needs to model the service interval rather than an average hourly flow. Set out:

  • the number of chapels and the service interval proposed
  • expected attendance per service, and the exceptional event figure
  • vehicle occupancy assumptions and the resulting parking demand
  • the internal circulation keeping an arriving cortege separate from a departing congregation
  • queueing capacity within the site so that no vehicle waits on the public highway
  • coach and minibus provision and turning

Internal queueing is the point highway authorities press hardest. A site where a cortege has to wait on a rural road for a gate to clear will attract an objection that is difficult to answer with anything other than a redesign.

Noise, privacy and the screening of mourners

Noise is a two-way issue. Plant and abatement equipment need assessing against the background sound level in the conventional way. Equally, the use itself needs protecting from external noise, because a service disturbed by a neighbouring industrial process is a legitimate planning concern.

Privacy takes more design attention here than in most applications. Mourners should not be visible from a public road or a neighbouring property while waiting, and arriving and departing groups should not meet. That drives the layout: separate entrance and exit, screened waiting areas, planting that gives enclosure within the first few years rather than after fifteen.

Set the privacy strategy out explicitly in the design and access statement. It is the element a planning committee will ask about.

Groundwater and the memorial garden

Ash scattering and interment of ashes in a memorial garden raise far smaller groundwater questions than a burial ground does, but the distinction has to be made in the submission rather than assumed.

Where the proposal includes any burial of remains, the environmental regulator expects a hydrogeological risk assessment addressing depth to groundwater, soil permeability, proximity to boreholes, springs and watercourses, and any source protection zone. Where the proposal is limited to ashes, say so and explain why the assessment is proportionate.

Surface water drainage for a large car park on a greenfield edge site is the bigger technical item. Attenuation, greenfield run-off rates and treatment before discharge all need designing in rather than added later.

Landscape, planting and long term management

The visual case is usually the one that decides the application. A Landscape and Visual Impact Assessment covering the building, the stack and the car park, with viewpoints agreed with the authority, is the core document, supported by a Landscape Strategy setting out planting, species and establishment.

Long term management is where crematorium schemes differ from most. The memorial garden is a permanent landscape with a maintenance obligation that continues indefinitely, and the authority will want it secured. Offer a management plan with a stated period and a mechanism rather than waiting for the condition to be drafted for you.

Trees on the site need surveying to BS 5837 before the layout is fixed, because mature boundary trees are usually the feature that makes the screening case work.

Consultees and the permitting authority

Expect the following to be consulted or engaged:

Body Interest
Local highway authority Access, visibility, internal circulation, queueing
Environmental health or regulatory services The environmental permit, plant noise, odour
Environmental regulator Groundwater where remains are interred, surface water discharge
Lead local flood authority Surface water drainage strategy
Parish or town council Local amenity, traffic, landscape
Nature conservation body Where a designated site lies nearby

The permit and the planning permission can be pursued in parallel, and doing so is usually sensible because each informs the other. What does not work is securing permission for a building whose plant room and stack were designed before the permit discussion began.

Enter your postcode on PlanScope to see which reports your site needs. For specialist technical reports, qualified professional input may be required. PlanScope provides AI-assisted draft reports for planning applications. Reports should be reviewed before submission. We do not guarantee planning approval. This is general guidance, not legal advice; check the position with your local planning authority or a qualified professional before relying on it.

Frequently asked questions

Which use class is a crematorium?

None. Crematoria fall outside the Use Classes Order as a sui generis use, so there is no permitted development route into the use and no movement within a class to rely on. Once established, the use also cannot change to something else without a further permission.

What siting distances apply?

Under the Cremation Act 1902 a crematorium may not be built within 200 yards of a dwelling house, except with the consent of the owner, lessee and occupier, nor within 50 yards of a public highway, nor in the consecrated part of a burial ground. Check the position for a site before any design work begins.

Who regulates emissions from the cremators?

The local authority, through a permit under the Environmental Permitting (England and Wales) Regulations 2016, with mercury abatement expectations set in the published process guidance for the sector. The planning application should explain that emissions are controlled through the permit rather than duplicating that assessment.

How is stack height determined?

By dispersion modelling that accounts for building downwash from the crematorium and nearby structures, not by architectural preference. The air quality assessment should state the modelled scenario, the receptors, the assumed emission rates and the resulting height, and the design then has to accommodate it honestly.

Why is the transport evidence unusual?

Because arrivals and departures cluster tightly around scheduled service times, with one cortege arriving as the previous congregation leaves. Modelling an average hourly flow misses the peak entirely. Internal queueing capacity, so that no vehicle waits on the public highway, is the point highway authorities press hardest.

Is a hydrogeological risk assessment needed?

Where remains are to be interred, the environmental regulator expects one, covering depth to groundwater, soil permeability, proximity to boreholes, springs and watercourses, and any source protection zone. Where the proposal is limited to the scattering and interment of ashes, say so and explain why a proportionate approach is justified.

Sources and further reading

crematoriumsui generisair qualitytransport assessmentlandscapeenvironmental permit

This article is general guidance about the planning system in England and, where stated, the rest of the UK. It is not legal or professional advice. Check your local planning authority’s validation requirements and take professional advice for your specific site.

More in Which Reports Do I Need

View all →
Which Reports Do I Need7 min read

Reports for a change of use to a place of worship

Class F.1 covers public worship, and most refusals turn on peak attendance parking rather than principle. The surveys, the management plan and the policy protecting the previous use.

Read article →
Which Reports Do I Need7 min read

Documents for a householder annexe in the garden

Living accommodation is never incidental, so Class E cannot deliver a self-contained annexe. The characterisation question, the drainage and tree evidence, and the condition the council will attach.

Read article →
Which Reports Do I Need7 min read

Planning documents for an HMO conversion from a house

Class L permits the change from a house to a small shared house, so everything turns on whether an Article 4 direction applies. The concentration test, room size standards, parking stress evidence and the plans an officer expects.

Read article →
Which Reports Do I Need7 min read

Reports for converting offices above a shop to flats

Natural light to every habitable room and noise from the commercial unit below decide most upper floor conversions. What Class MA prior approval covers, what it cannot consider, and the documents each route needs.

Read article →
Which Reports Do I Need6 min read

Which reports a scheme with a public right of way needs

Recorded rights of way need an order under section 257 or the Highways Act before a scheme can build over them. The timing trap, the objection risk and the evidence to submit.

Read article →
Which Reports Do I Need7 min read

Which reports a scheme with a culverted watercourse needs

A culvert brings a second consent regime under the Land Drainage Act 1991. How to find it, who consents what, why deculverting usually wins, and the reports the submission needs.

Read article →