Which Reports Do I Need

Reports for a shisha lounge in a parade of shops

8 min readBy PlanScope Editorial Team

A shisha lounge is usually sui generis, and its application turns on a contradiction: the smoke-free definition of substantially enclosed forces an open shelter that amenity policy resists.

Shisha lounge planning reports have to answer a problem no other food and drink use faces: the smoke-free legislation pushes the smoking area outdoors, and planning policy wants it enclosed. You cannot satisfy both with the same structure, and an application that does not confront the tension openly gets refused on amenity grounds. The bundle a council will expect is a Planning Statement, a Design and Access Statement, an extraction and odour assessment, noise evidence covering both plant and customers, a waste strategy and, inside an air quality management area, an air quality assessment.

There is no use class called shisha. That is where the application starts.

Use class and why the use is usually sui generis

Class E(b) covers the sale of food and drink for consumption mostly on the premises. A shisha lounge sells food and drink, so an applicant will often argue E(b) and sometimes succeed. Councils more commonly treat the use as sui generis, because the characteristic activity is the supply and smoking of shisha rather than the sale of food, and the planning consequences of that activity are different in kind from a café.

The use is characterised by what actually happens on the premises, not by the name over the door or the description on the form. A lounge where most customers come to smoke, stay for two hours and order mint tea is not a café with an unusual sideline.

So assume sui generis and apply on that basis. It is the safer position, it gives the officer a description that can be conditioned, and it avoids an enforcement notice two years later alleging a material change of use from a café. If the premises were previously a hot food takeaway, that was already sui generis after the 2020 amendment to the Use Classes Order, so there is no permitted route across either way.

Extraction, termination height and what the officer checks

Shisha smoke is a combustion product, not a cooking odour, and the extract system has to be designed for it. Environmental health officers check four things on the drawings.

  1. The capture arrangement at the point of use, which for table service means a local extract hood or a ducted table rather than general room ventilation.
  2. The duct route, its material and whether it passes through the flats above, which almost always needs the freeholder's agreement and fire stopping at every compartment line.
  3. The termination point and height. Councils commonly require discharge at least a metre above the ridge of the building and clear of any openable window or air intake within a stated distance, following the Defra guidance on controlling odour and noise from commercial kitchen exhaust systems.
  4. The abatement, which for combustion products usually means filtration in stages and, where officers are unconvinced, carbon.

A flue clipped to the rear elevation terminating at first-floor level is the single most common reason these applications fail. Where the building has residential above, the vertical duct has to go somewhere and the structural and ownership questions are harder than the planning ones. Resolve them before you apply.

An Odour Assessment should state the sources, the extract volume, the termination height above ridge and the filtration specification, and it should say what residual odour is expected at the nearest window. An assessment that describes the equipment without predicting an effect gives the officer nothing to condition.

The smoke-free rules and the shelter they force you to build

Smoking in enclosed and substantially enclosed premises is prohibited under the Health Act 2006 and the regulations made under it. Substantially enclosed has a definition: a structure with a ceiling or roof where the openings in the walls amount to less than half of the total wall area. So a legal shisha area needs openings of at least half the wall area, or no roof at all.

That is a planning problem rather than a solution. An open-sided shelter in a rear yard behind a parade of shops puts conversation, music and smoke directly into the gardens or flats behind, at the hours when they are most sensitive. An officer who understands the smoke-free rule will ask what the shelter does for the neighbours, and an applicant who proposes a fully enclosed heated structure is either breaking the smoking ban or not really using it for shisha.

The honest designs that get through tend to combine several things rather than rely on one.

  • Siting the shelter against the building and away from the shared boundary, using the building itself as the acoustic barrier.
  • A solid parapet to seated head height on the boundary side, with the required openings taken from the side facing the building.
  • An absorptive soffit under the roof, which reduces reverberant build-up without closing the structure.
  • A hard capacity limit, offered as a condition, with the number of seats fixed on the drawing.
  • An earlier curfew on the outdoor area than on the indoor premises.

Local authorities enforce the smoke-free legislation themselves, often through the same environmental health team that comments on the planning application, so inconsistency between the two will be noticed.

Late-night noise from customers outside

The planning objections come from departures, not from the premises. A lounge trading to 1am empties onto a shopping street at closing time, and the complaint pattern that follows is car doors, raised voices and engines rather than anything measured inside the building.

Fixed plant is the easy part, assessed as a rating level against measured background under BS 4142:2014+A1:2019, with the extract fan and any air conditioning enclosed and set back at night. A Noise Impact Assessment should treat customers separately, with stated assumptions about numbers and timing, and should present the controls rather than a prediction dressed up as one.

What carries weight is the management detail. A dispersal plan naming the route customers are directed to, a limit on the number of people in the outdoor area after a stated hour, no amplified sound outside at any time, a staff member responsible for the frontage at closing, and a published contact for complaints. All of those can be conditioned, and offering them unprompted shifts the officer's starting position.

Charcoal, ash and waste handling

Spent charcoal leaves the premises hot. It needs a metal bin with a lid, sited away from combustible material and away from the duct, and it needs a documented cooling period before transfer. Show the bin on the site plan with its position dimensioned.

Commercial waste is subject to the duty of care in section 34 of the Environmental Protection Act 1990, so the application should name the arrangements rather than describe them vaguely. Volumes from a shisha lounge are modest but awkward: ash, foil, disposable mouthpieces and glassware, plus food waste if there is a kitchen. A Waste Management Strategy covering storage location, capacity, collection frequency and the collection point on the highway is a short document that removes an objection.

Where the premises sit inside an air quality management area, the authority will want an Air Quality Assessment covering the combustion emissions and any additional vehicle movements. The approach is the same one set out in our note on reports for an industrial extension inside an AQMA, and the assessment is one where councils expect a suitably qualified author with professional review before submission.

Fire risk and which document actually covers it

Charcoal combustion indoors raises carbon monoxide risk, and the grease and tar loading in a shisha extract duct is a fire path. Both are real and neither is a planning matter in the way applicants expect.

A Fire Statement under Article 9A of the Development Management Procedure Order is required only for relevant buildings under the Building Safety Act framework, which means residential and certain other buildings of 18 metres or seven storeys. A single-storey unit in a shopping parade does not need one. The controls that apply are the fire risk assessment required by the Regulatory Reform (Fire Safety) Order 2005, duct cleaning regimes, carbon monoxide detection and the building regulations approval for the works.

Say that plainly in the planning submission rather than leaving a gap. An officer reading about charcoal and a long duct will ask the question, and the answer is that the risk is controlled under a different regime, with the specific measures named. For specialist technical reports, qualified professional input may be required.

Hours and the conditions that make the use acceptable

Element What to offer
Indoor opening hours A defined closing time, usually earlier on Sunday to Thursday
Outdoor area hours A curfew ahead of indoor closing, with no amplified sound
Capacity Seat numbers fixed on the approved drawing, indoors and out
Extraction Installation to the approved specification before first use, with a maintenance regime
Waste Approved store location and collection arrangements
Dispersal A management plan approved before first use and reviewable

Offer the hours rather than waiting to be told. A lounge that applies for 2am and accepts midnight has had a negotiation. A lounge that applies for midnight with a dispersal plan and a seat cap has made a case.

Enter your postcode on PlanScope to see which reports a sui generis change of use in a shopping parade is likely to need. This is general guidance, not legal advice. Check the position with your local planning authority or a qualified professional before relying on it.

PlanScope provides AI-assisted draft reports for planning applications. Reports should be reviewed before submission. We do not guarantee planning approval.

Frequently asked questions

Which use class is a shisha lounge?

There is no class that names shisha. Councils commonly treat the use as sui generis because the characteristic activity is supplying and smoking shisha rather than selling food, even though food and drink are served. Applying on a sui generis basis is safer, gives the officer a description that can be conditioned, and avoids a later enforcement allegation.

How high must the extract flue terminate?

Councils commonly require discharge at least a metre above the ridge of the building and clear of any openable window or air intake within a stated distance, following Defra guidance on controlling odour and noise from commercial kitchen exhaust systems. A flue terminating at first-floor level on a rear elevation is the most frequent reason these applications fail.

Can a shisha shelter be enclosed?

Not if shisha is to be smoked in it. The Health Act 2006 regulations prohibit smoking in substantially enclosed premises, defined as a structure with a ceiling or roof where openings in the walls total less than half the wall area. A fully enclosed heated structure is therefore either unlawful for smoking or not being used for it.

Does a shisha lounge need a Fire Statement?

Normally no. A Fire Statement under Article 9A of the Development Management Procedure Order applies to relevant buildings under the Building Safety Act framework, broadly those of 18 metres or seven storeys. A unit in a shopping parade is controlled instead by the fire risk assessment required under the Regulatory Reform (Fire Safety) Order 2005 and by building regulations.

What noise evidence does a council expect?

Two separate exercises. Fixed plant assessed as a rating level against measured background under BS 4142:2014+A1:2019, and customer and departure noise handled through management controls with stated assumptions. A dispersal plan, an outdoor capacity limit after a set hour, no amplified sound outside and a named contact for complaints carry more weight than modelling.

How should spent charcoal be stored?

In a lidded metal bin, positioned away from combustible materials and away from the duct, with a documented cooling period before transfer. Show the bin dimensioned on the site plan. Commercial waste is subject to the duty of care in section 34 of the Environmental Protection Act 1990, so name the collection arrangements rather than describing them loosely.

Sources and further reading

shisha loungesui generischange of useextractionodour assessmentnoise

This article is general guidance about the planning system in England and, where stated, the rest of the UK. It is not legal or professional advice. Check your local planning authority’s validation requirements and take professional advice for your specific site.

More in Which Reports Do I Need

View all →
Which Reports Do I Need8 min read

Reports for a caravan storage compound on farmland

Storing unoccupied touring caravans on a field is a material change of use. The application is decided by winter visibility of the stored units and by what the hardstanding does to runoff.

Read article →
Which Reports Do I Need8 min read

Reports for a nursery in a former community hall

A community hall sits in Class F2 and a day nursery in Class E(f), so the change needs permission. The reports that decide it turn on the drop-off peak and on how children's voices are assessed.

Read article →
Which Reports Do I Need7 min read

Reports for a car body repair workshop near housing

Panel beating is impulsive noise and a spray booth discharges solvent vapour near bedroom windows. Those two facts set the evidence base for a body shop application beside housing.

Read article →
Which Reports Do I Need7 min read

Reports for a climbing centre in a redundant church

A climbing centre in a redundant church turns on three documents: the heritage case for fixings into historic fabric, the fire strategy for a tall single volume, and the structural evidence behind both.

Read article →
Which Reports Do I Need8 min read

Reports for a mosque in a converted warehouse

A warehouse-to-mosque change of use stands or falls on the Friday peak. Here is how to build the parking, highway, noise and capacity evidence a case officer will test.

Read article →
Which Reports Do I Need7 min read

Reports for a veterinary hospital with overnight care

Overnight care changes the use class question and the evidence base. Animal noise at night is the issue that refuses these applications, and it needs structural mitigation.

Read article →