Which Reports Do I Need

Which reports a funeral directors in a former bank needs

6 min readBy PlanScope Editorial Team

Moving a funeral directors into a former bank may not need permission for the use at all. The works, the hearse access and the mortuary ventilation are a different matter.

The funeral directors planning reports you need depend first on a question most agents get wrong: whether the use falls inside Class E at all. A former bank is Class E(c)(i), financial services. Movements within Class E are not development, so if a funeral directors also sits within Class E there is no change of use to apply for and the application is about the works alone.

The honest answer is that the position is arguable and depends on what happens on the premises. Before the 2020 amendments, use "for the direction of funerals" was expressly listed within Class A1. When Class A1 was replaced, that list disappeared, and the natural successor is Class E(c)(iii), services appropriate to provide in a commercial, business or retail district to visiting members of the public. A reception office arranging funerals fits that description comfortably.

Where the use sits, and how to find out for certain

What takes a funeral directors outside Class E is the back of house. Body storage in refrigerated units, embalming and preparation, and a chapel of rest are not services provided to visiting members of the public in the ordinary sense, and several authorities treat premises with those facilities as sui generis. Where the premises are a shopfront office with arrangements made by appointment and the deceased kept elsewhere, the Class E argument is strong.

Two routes give certainty rather than an opinion:

  1. A pre-application enquiry, which gives you the case officer's view in writing but binds nobody.
  2. An application for a certificate of lawfulness of proposed use or development under section 192 of the Town and Country Planning Act 1990, which produces a formal determination that the proposed use would be lawful without permission.

A lawful development certificate is the only formal way to confirm that works or a use are lawful. If the scheme involves a large fit-out spend, the certificate fee is modest insurance against an enforcement notice two years later.

What the works need regardless of the use question

Even where the use falls within Class E, a former bank conversion almost always involves development that needs permission. Banking halls have deep plans, high ceilings, heavy security shutters and blank or obscured ground floor glazing, and the alterations to make one work as funeral premises are extensive.

Expect to need permission for a new or altered shopfront, external plant for refrigeration and ventilation, a new rear or side access for the hearse and for discreet arrival, changes to windows at ground floor for privacy, external signage under advertisement consent, and any extension or rear infill. Each of those carries its own evidence requirement, and the Planning Statement is where the whole package gets explained in one place.

Vehicle access, hearse standing and parking

This is the issue that generates the most officer correspondence. A funeral directors needs a hearse and limousines to arrive and leave without reversing into a busy high street, a discreet point for the arrival of the deceased away from public view, and somewhere for a cortege to form up without blocking the carriageway.

Matter Evidence that answers it
Hearse and limousine access Swept path drawings for the actual vehicles, entering and leaving in forward gear
Discreet arrival A plan showing the covered or screened arrival point and its relationship to public views
Cortege formation A layout showing where vehicles wait, and for how long
Staff and visitor parking Provision against the adopted standard, with an accessible space
Loss of former bank parking Whether the existing provision is retained or reduced

Where the site has no off-street provision, the argument has to be made on the trip profile rather than on hope. Funeral premises generate very few trips across the day compared with a bank branch, concentrated into short periods, and a Transport Statement that sets out expected funeral numbers per week and the duration of each movement is more persuasive than a general claim about low activity.

Ventilation, refrigeration and plant

Mortuary and preparation areas need mechanical ventilation with a discharge point, and body storage needs refrigeration with external condensers. Both are external plant on what is usually a party wall or a rear elevation in a town centre, often with flats above or behind.

The planning questions are noise and position, not clinical standards. A Noise Impact Assessment measured against the night-time background is the usual requirement where there is residential accommodation within earshot, because refrigeration runs continuously. The ventilation discharge needs a stated termination point clear of openable windows, which belongs in a Ventilation and Extraction Statement alongside the plant schedule.

Odour is rarely the determining issue for funeral premises, which surprises applicants who expect it to be. Officers are far more concerned about continuous plant noise and about the visual effect of condensers on a listed or locally distinctive rear elevation.

Shopfront design and the heritage question

Former banks are disproportionately listed or locally listed, and they are disproportionately in conservation areas, because they occupied the best corner sites in Victorian and Edwardian high streets. Check the National Heritage List for England and the authority's local list before you design anything.

Where the building is listed, changing the shopfront, removing internal joinery, cutting through a vault or fixing signage all need listed building consent in addition to planning permission, and the test under the Planning (Listed Buildings and Conservation Areas) Act 1990 is the special regard the authority must have to preserving the building and its features of special interest. A Heritage Statement setting out significance, the effect of each element of the proposal, and the justification for any harm is the document that carries the case. Blank or heavily obscured ground floor glazing is the element most often resisted, and etched or film treatments with a legible shopfront behind are the usual compromise.

Hours, servicing and the conditions to expect

Funeral premises get lighter conditions than most town centre uses, because the activity is quiet and daytime. The ones that recur are a restriction on the hours during which the preparation and storage areas may be serviced, a requirement for the plant to meet a stated rating level at the nearest residential facade, approval of the shopfront and signage details, retention of the approved vehicle access and turning area, and in some cases a restriction tying the permission to the funeral use rather than to the wider class.

That last condition is worth reading carefully. A condition limiting the use to a funeral directors removes the Class E flexibility a future occupier would otherwise have, and it reduces the value of the lease. Resist it where the authority cannot explain what harm it prevents.

And on the document list, keep it proportionate. A high street unit does not need a transport assessment, an air quality assessment or an ecology survey. The pack is normally a planning statement, a design and access statement where the authority's local list requires one, a heritage statement where the building or area is designated, a transport statement covering access and servicing, a plant noise assessment, and a ventilation and extraction statement.

This is general guidance, not legal advice. Use class interpretation turns on the facts of each case, and local validation requirements change, so check the position with your local planning authority or a qualified professional before relying on it.

PlanScope provides AI-assisted draft reports for planning applications. Reports should be reviewed before submission. We do not guarantee planning approval.

Frequently asked questions

Is a funeral directors within Class E?

It is arguable and depends on the facilities. A reception and arrangement office providing a service to visiting members of the public fits Class E(c)(iii), the successor to the old Class A1 reference to the direction of funerals. Premises with body storage, embalming and a chapel of rest are often treated as sui generis instead, so confirm the position before committing to a fit-out.

Do I need permission to move from a bank into funeral premises?

If both uses fall within Class E, the change itself is not development and no permission is needed for the use. The works almost always need permission, including a new shopfront, external plant, altered access and signage. Where the classification is uncertain, a certificate under section 192 of the Town and Country Planning Act 1990 gives a formal answer.

What access evidence does a funeral directors application need?

Swept path drawings for the hearse and limousines showing entry and exit in forward gear, a plan identifying the discreet arrival point for the deceased, somewhere for a cortege to form without blocking the carriageway, and parking provision against the adopted standard. A short transport statement setting out funeral numbers per week carries more weight than a general claim of low activity.

Will neighbours object to mortuary ventilation and refrigeration?

Noise is the usual concern rather than odour, because refrigeration condensers run continuously and are often mounted on a rear elevation close to flats. A noise assessment measured against the night-time background, with a condition fixing the rating level at the nearest residential facade, is the normal resolution. The ventilation discharge point must be clear of openable windows.

Should I accept a condition limiting the premises to funeral use?

Think carefully before agreeing. Such a condition removes the Class E flexibility that a future occupier would otherwise have and reduces the letting value. Conditions must be necessary and relevant to planning, so ask the authority to explain what harm the restriction prevents, and negotiate it out where no answer is forthcoming.

Sources and further reading

funeral directorsclass echange of useformer bankheritagecommercial occupier

This article is general guidance about the planning system in England and, where stated, the rest of the UK. It is not legal or professional advice. Check your local planning authority’s validation requirements and take professional advice for your specific site.

More in Which Reports Do I Need

View all →
Which Reports Do I Need7 min read

Reports for a vertical farm in a warehouse

A controlled environment vertical farm in an existing warehouse needs permission, and the use class is unsettled. Grid capacity, light spill, plant noise and trade effluent drive the evidence.

Read article →
Which Reports Do I Need7 min read

Reports for a dental practice in a converted house

A house to dental surgery conversion needs full permission for a change of use from Class C3 to Class E(e). Parking demand and plant noise are what actually decide the application.

Read article →
Which Reports Do I Need8 min read

Reports for a parcel locker and courier hub

A last mile courier hub needs transport, noise, drainage and utilities evidence shaped around pre-dawn van departures and fleet charging load, not warehouse trip rates.

Read article →
Which Reports Do I Need7 min read

Reports for a film studio on an industrial estate

There is no use class for a film studio, and standard industrial trip rates do not describe one. The evidence base is noise, lighting, grid capacity and transport, with a fire strategy for undivided stages.

Read article →
Which Reports Do I Need8 min read

Reports for a caravan storage compound on farmland

Storing unoccupied touring caravans on a field is a material change of use. The application is decided by winter visibility of the stored units and by what the hardstanding does to runoff.

Read article →
Which Reports Do I Need8 min read

Reports for a shisha lounge in a parade of shops

A shisha lounge is usually sui generis, and its application turns on a contradiction: the smoke-free definition of substantially enclosed forces an open shelter that amenity policy resists.

Read article →