Which Reports Do I Need

Reports needed for a rear dormer loft conversion

7 min readBy PlanScope Editorial Team

A rear dormer is often permitted development under Class B, so the paperwork is a certificate and a drawing set. Where it is not, the bat survey season usually sets the timetable.

A rear dormer loft conversion on an ordinary two-storey house is often permitted development, in which case the only paperwork is a lawful development certificate application and a drawing set. Where it is not permitted development, the pack is a householder application: forms, certificates, location plan, block plan, existing and proposed plans, sections, elevations and the fee. The report that catches people out in both cases is the bat survey, because roof works are the classic trigger and the survey season runs from May to September.

When a rear dormer is permitted development

Class B of Schedule 2 Part 1 of the General Permitted Development Order covers enlargement of a house by an addition or alteration to its roof. The limits that decide most loft conversions are these.

  • A volume allowance of 40 cubic metres for a terraced house and 50 cubic metres for any other house, measured as the total of all roof enlargements including any made by a previous owner.
  • Nothing may extend beyond the plane of the existing roof slope that fronts a highway, which is why rear dormers are common and front dormers are not.
  • No part may be higher than the highest part of the existing roof.
  • Materials must be similar in appearance to the existing house.
  • No verandas, balconies or raised platforms.
  • Side-facing windows must be obscure-glazed and non-opening below 1.7 metres above the floor.
  • Except for a hip-to-gable enlargement, the roof extension must be set back at least 20 centimetres from the original eaves.

Class B does not apply at all on Article 2(3) land, which means conservation areas, National Parks, National Landscapes and World Heritage Sites. A rear dormer in a conservation area needs planning permission, full stop, and usually a Heritage Statement explaining the roof form, materials and window pattern.

Rooflights sit under Class C instead, which permits alterations that do not protrude more than 150 millimetres beyond the roof plane and are not higher than the ridge.

Two practical traps. The volume allowance counts previous roof enlargements, so a house that already has a small dormer has less headroom than the owner assumes. And permitted development rights can be removed by an Article 4 direction or by a condition on the original planning permission for the estate, which is common on developments built since the 1980s.

The drawing set councils expect

Whether you are applying for a certificate or for permission, the same drawings do the work. Roof alterations are judged in section more than in elevation, so a scheme drawn only in plan and elevation is usually returned.

  1. Location plan at 1:1250 with the site edged red.
  2. Existing and proposed roof plans at 1:100 or 1:50.
  3. Existing and proposed rear and side elevations at the same scale, showing the ridge line, eaves line and the 20 centimetre set-back where it applies.
  4. Existing and proposed sections through the dormer, showing floor levels, head heights and the relationship to the ridge.
  5. A volume calculation where the scheme relies on Class B, set out clearly enough that an officer can check it.

Draw the set-back dimension on the section and annotate it. Officers checking a certificate application are looking for a reason to be satisfied, and an undimensioned drawing gives them none.

Bats: the survey nobody budgets for

All UK bat species are protected under the Wildlife and Countryside Act 1981 and the Conservation of Habitats and Species Regulations 2017. It is an offence to damage or destroy a breeding site or resting place, whether or not bats are present at the time, and roof voids are exactly where roosts occur.

Councils increasingly ask for a preliminary roost assessment with any application involving roof works on an older building, a building with gaps at the ridge or verge, or a property near woodland or water. The assessment is an inspection, done at any time of year, by an ecologist. If it finds evidence or moderate potential, emergence and re-entry surveys follow, and those can only be done between May and September, with May to August the more reliable window.

This is not optional and it is not something an AI draft can substitute for. A Protected Species Survey and any subsequent mitigation licence must be carried out by a suitably licensed ecologist. Where a roost is confirmed, a European protected species mitigation licence from Natural England is required before the works start, and that is a separate process from planning permission with its own timescale.

Plan for it. A conversion approved in October with an outstanding emergence survey requirement will not start until the following May.

Fire escape and the questions that follow

A loft conversion on a two-storey house creates a third storey, and Approved Document B then requires a protected stairway from the loft to a final exit, fire doors to habitable rooms off that stair, and mains-wired interlinked smoke alarms. Where a protected stair cannot be formed, alternative approaches such as a sprinkler system under BS 9251 are sometimes accepted by the building control body.

None of that is a planning matter, and a planning officer will not refuse a dormer because the stair is wrong. But it changes the design, because the protected stair usually dictates where the new stair lands and therefore where the dormer goes. Resolve it with your building control body before the planning drawings are fixed rather than after.

The questions the planning officer will raise are different: whether the dormer is subordinate to the roof, whether it sits below the ridge and above the eaves, whether the flank window overlooks a neighbouring garden, and whether the materials read with the existing roof.

Illustrative document list for a hip-to-gable and dormer

Illustrative example. A mid-1930s end-of-terrace outside a conservation area, hip-to-gable to one side with a full-width box dormer to the rear, total roof enlargement within the 40 cubic metre terrace allowance.

  • Lawful development certificate application for proposed works, with the fee at the reduced certificate rate.
  • Location plan, existing and proposed roof plans, elevations and two sections.
  • A volume calculation showing the hip-to-gable and the dormer separately and totalled.
  • A note confirming the side window will be obscure-glazed and fixed below 1.7 metres.
  • A preliminary roost assessment, because the roof is being opened up on a ninety-year-old building.
  • Confirmation from the deeds that no condition removed permitted development rights.

If the same house sat inside a conservation area, the certificate route disappears and the list becomes a householder planning application with a heritage statement and, quite likely, a request to reduce the dormer and use conservation rooflights instead.

Confirming lawfulness with a certificate

Permitted development is a legal position, not an official approval, and nobody at the council checks it unless you ask. A certificate of lawfulness for proposed use or development under section 192 of the Town and Country Planning Act 1990 is the formal way to confirm that the works are lawful.

It is worth having for three reasons. It settles the volume calculation before you build rather than after a complaint. It satisfies conveyancing solicitors on sale, who now ask for one as a matter of routine. And it removes the enforcement risk that a neighbour's report would otherwise create.

The fee is lower than a full householder application, and the determination period is the same eight weeks. Apply for it while the scaffolding is still being priced.

Browse the 66 PlanScope report types to see which supporting documents a roof scheme usually needs, and enter your postcode on PlanScope to check what your site triggers. PlanScope provides AI-assisted draft reports for planning applications. Reports should be reviewed before submission. We do not guarantee planning approval. This is general guidance rather than legal advice, and a lawful development certificate is the only formal way to confirm that works are lawful.

Frequently asked questions

How big can a rear dormer be under permitted development?

Class B allows a total roof enlargement of 40 cubic metres on a terraced house and 50 cubic metres on any other house, counting any previous roof additions. The dormer must not exceed the height of the existing ridge, must not front a highway, and except for hip-to-gable work must be set back at least 20 centimetres from the original eaves.

Can I build a rear dormer in a conservation area?

Not under permitted development. Class B is excluded on Article 2(3) land, which includes conservation areas, National Parks, National Landscapes and World Heritage Sites, so a planning application is needed. Councils in those areas often prefer conservation rooflights or a smaller dormer set well below the ridge, guided by the area's character appraisal.

Do I really need a bat survey for a loft conversion?

Often yes, where the building is older, has gaps at the ridge or verge, or sits near woodland or water. A preliminary roost assessment can be done at any time of year. If it finds evidence or moderate potential, emergence surveys follow and can only be carried out between May and September, which can delay a scheme by months.

Is a lawful development certificate worth applying for?

Yes, if you are relying on permitted development. It confirms formally that the works are lawful, settles the volume calculation before you build, satisfies conveyancing enquiries on a later sale, and removes the enforcement risk from a neighbour's complaint. The fee is lower than a householder application and the determination period is eight weeks.

Does a loft conversion need building regulations approval too?

Always. Creating a third storey brings Approved Document B requirements for a protected stairway, fire doors to habitable rooms and interlinked mains-wired smoke alarms. Building control is a separate process from planning, but it shapes the design because the protected stair usually determines where the new stair and the dormer can go.

Sources and further reading

loft conversiondormerpermitted developmentbat surveyhouseholder

This article is general guidance about the planning system in England and, where stated, the rest of the UK. It is not legal or professional advice. Check your local planning authority’s validation requirements and take professional advice for your specific site.

More in Which Reports Do I Need

View all →
Which Reports Do I Need7 min read

Reports for a rooftop pool on a flat conversion

A rooftop pool on a converted block turns on three pieces of evidence: the weight of water on the existing structure, the noise of wet plant, and what the enclosure does to the roofline.

Read article →
Which Reports Do I Need7 min read

Reports for a sand and gravel extension of six hectares

A six hectare gravel extension is decided by the mineral planning authority, needs an EIA screening opinion, and turns on hydrogeology and restoration rather than on blasting.

Read article →
Which Reports Do I Need6 min read

Reports for a traveller site with four pitches

A four pitch traveller site is a minor application with a major policy test. Need evidence, pitch separation and flood vulnerability decide most of these cases.

Read article →
Which Reports Do I Need7 min read

Reports for a micro hydro scheme on a weir

Micro hydro at a weir needs planning permission plus abstraction, impoundment and flood risk permits. The fish pass is often the costliest item, and it has to be settled before the drawings.

Read article →
Which Reports Do I Need7 min read

Reports for a student accommodation scheme of 200 beds

A 200 bed student scheme is a major application with two documents that have no equivalent on a standard residential pack: the institutional need case and the student management plan.

Read article →
Which Reports Do I Need7 min read

Reports needed for a church hall replacement

Rebuilding a church hall means answering three questions at once: the community facility replacement test, the setting of the adjoining listed church, and what lies under a churchyard.

Read article →