Which Reports Do I Need

Which reports a 60-bed care home application needs

6 min readBy PlanScope Editorial Team

A 60-bed home is major development on floorspace and site area, not on dwelling numbers. Here is the evidence base, and the two work streams that set the submission date.

A 60-bed care home is major development, but not for the reason most people assume. Care homes fall in Class C2, residential institutions, so they are not counted in dwellings and the ten-unit trigger never applies. What makes the scheme major is floorspace and site area, and a 60-bed home will comfortably exceed 1,000 m² of new floorspace on a site approaching a hectare.

That single classification decision changes the determination period, the consultation, the fee and most of the care home planning reports you have to commission.

C2 and why the thresholds bite differently

Class C2 covers residential accommodation and care to people in need of care, along with residential schools, colleges and hospitals. A care home providing personal or nursing care sits squarely in it.

Extra care and assisted living schemes are the grey area. Where residents occupy self-contained homes with their own front doors and buy care as a separate service, the use can fall in Class C3 instead, and that changes everything. A C3 scheme counts as dwellings, so the ten-unit affordable housing threshold, the biodiversity net gain small sites position and the housing land supply arguments all apply to it.

Settle that question first, in writing, with the case officer. Two schemes of identical appearance can face entirely different policy tests, and the description of development on the application form is where the argument starts.

What crossing 1,000 m² adds

Major development for a non-residential building means 1,000 m² or more of floorspace, or a site of one hectare or more. Once the proposal is major, four things follow.

  • The determination period becomes 13 weeks rather than eight.
  • The publicity requirements increase, usually a press notice and a site notice.
  • The application fee is calculated on the major scale.
  • Statutory consultees and internal specialists are engaged more fully, including the lead local flood authority and the highway authority.

At 2,500 m² or more, a Transport Assessment rather than a shorter statement is the expectation, and a 60-bed home is usually close to or above that figure once ancillary space is counted.

Biodiversity net gain applies. The statutory metric has to be completed by a competent person and the biodiversity gain plan approved by the authority before development begins, so the ecology work belongs at the front of the programme rather than at the discharge of conditions stage.

Nutrient neutrality is the constraint that catches care home schemes in affected catchments. A care home provides overnight accommodation, so it adds population to the catchment in the same way as housing, and mitigation has to be secured before permission can be granted. Check the catchment position before you buy the site.

Trip generation, shifts and ambulance access

Care home traffic looks light and behaves oddly. Resident trips are close to zero, and almost all movement comes from staff shift changes, visitors, deliveries, healthcare visits and emergency vehicles.

Three shift changes a day produce three small peaks, and the early one often falls before public transport starts running, which drives the staff parking requirement whatever the local standard says. Build the assessment around a staffing rota rather than around bed numbers.

The access design has to work for the largest vehicle that will use it. An ambulance needs to reach a covered entrance, turn and leave without reversing into the highway. A private ambulance and a funeral director need a discreet arrival point away from the main entrance and from resident lounges, and a scheme without one attracts comment at committee.

Servicing is heavier than people expect. Catering deliveries, clinical waste collection, laundry and refuse all arrive by vehicle, and the swept path drawing should show each.

Amenity, daylight and outdoor space for residents

The occupants spend almost all their time inside the building, which changes how the amenity assessment should be written.

Daylight into lounges and bedrooms matters more here than in general housing, and a north-facing single aspect lounge is difficult to defend. Outdoor space should be secure, level, sheltered and reachable from the communal areas without steps, and dementia-friendly design guidance on legibility, contrast and wayfinding is worth reflecting in the design and access statement.

Overlooking works in both directions. Ground floor bedrooms facing a boundary need screening or a level change, and neighbours facing new balconies or terraces need the same consideration they would get on a housing scheme.

A Health Impact Assessment is required by some authorities on schemes of this scale, and it is the document that ties the design decisions to the outcomes for residents rather than listing them.

Fire, energy and overheating for a vulnerable occupancy

Vulnerable occupancy raises the standard of every environmental assessment.

Overheating is the clearest example. A building occupied 24 hours a day by people with limited mobility and reduced thermoregulation cannot rely on openable windows and personal adaptation. An Overheating Risk Assessment modelled under CIBSE TM59, which contains a specific criterion for bedrooms occupied by vulnerable people, is the analysis to commission, alongside compliance with Approved Document O.

Fire strategy runs in parallel. Progressive horizontal evacuation, compartmentation and sprinkler provision shape the plan form from the beginning, and retrofitting them after a layout is fixed rarely works. Where the building reaches the height thresholds that engage Planning Gateway One, a Fire Statement is required with the application under Article 9A of the Development Management Procedure Order 2015, and it must be prepared by someone with the necessary fire engineering competence. Care settings have their own treatment under the Building Safety Act regime, so confirm the position for your building rather than applying a housing rule of thumb.

Energy and carbon follow the local plan. Continuous heating demand and high hot water loads make care homes different from housing in the modelling, and a heat pump strategy needs plant space and acoustic treatment designed in.

Illustrative evidence base for a 60-bed home on 0.9 ha

This list is illustrative and should be checked against the authority's validation list.

  1. Planning statement and design and access statement, with the use class question addressed directly.
  2. Transport assessment built on a staffing rota, with swept paths for ambulance, refuse and delivery vehicles, plus a travel plan.
  3. Flood risk assessment and drainage strategy, since the site exceeds one hectare in area on many schemes of this size.
  4. Preliminary ecological appraisal, protected species surveys as triggered by it, and the biodiversity metric with a draft gain plan.
  5. Arboricultural survey to BS 5837:2012 where trees are present.
  6. Overheating assessment to CIBSE TM59 and an energy statement.
  7. Fire statement where the building engages Article 9A, and a fire strategy in any event.
  8. Health impact assessment and, in some authorities, a social infrastructure assessment.
  9. Noise assessment covering plant, deliveries and any nearby road or rail source.
  10. Nutrient neutrality mitigation evidence where the site sits in an affected catchment.

Programme the ecology and nutrient work first. Those two items set the submission date more often than the design does.

To scope the full document set against your site's constraints, browse the index of report types by category or enter the postcode on PlanScope. This is general guidance, not legal advice. Check the position with your local planning authority or a qualified professional before relying on it. PlanScope provides AI-assisted draft reports for planning applications. Reports should be reviewed before submission. We do not guarantee planning approval. For specialist technical reports, qualified professional input may be required.

Frequently asked questions

Is a care home Class C2 or Class C3?

A home providing personal or nursing care is Class C2. Extra care and assisted living schemes where residents occupy self-contained homes and buy care separately can fall in Class C3, which brings the affordable housing threshold and housing land supply arguments with it. Settle the classification in writing with the case officer before the description of development is fixed.

What makes the application major development?

For a non-residential building, 1,000 m2 or more of floorspace or a site of one hectare or more. A 60-bed home clears the floorspace figure comfortably. That means a 13-week determination period, expanded publicity, the major fee scale and fuller engagement of statutory consultees.

How should trip generation be calculated?

From a staffing rota rather than from bed numbers. Resident trips are close to zero and almost all movement comes from shift changes, visitors, healthcare visits, deliveries and emergency vehicles. The earliest shift often starts before public transport runs, which drives the staff parking case whatever the local standard says.

Why does overheating need special attention?

Residents are present around the clock, may have limited mobility and cannot adapt easily to high internal temperatures. CIBSE TM59 contains a specific criterion for bedrooms occupied by vulnerable people, and that modelling, alongside Approved Document O compliance, is what a council's environmental health team will expect to see.

Does nutrient neutrality apply to care homes?

In affected catchments, yes. A care home provides overnight accommodation and therefore adds population to the catchment in the same way housing does, so mitigation has to be secured before permission can be granted. Check the catchment position before acquiring the site, because mitigation supply is limited in some areas.

Sources and further reading

care homeclass c2major developmenttransport assessmentoverheatingwhich reports

This article is general guidance about the planning system in England and, where stated, the rest of the UK. It is not legal or professional advice. Check your local planning authority’s validation requirements and take professional advice for your specific site.

More in Which Reports Do I Need

View all →
Which Reports Do I Need7 min read

Which reports a dental or medical surgery change of use needs

A dental or medical surgery sits within Class E(e), which means the change of use is often not development at all. The documents that matter are the ones about parking turnover, plant noise and waste storage.

Read article →
Which Reports Do I Need7 min read

Shop front replacement: which consents and reports you need

Replacing a shop front and its signage normally runs through two separate consent regimes at once. This explains which one catches what, where deemed consent runs out, and the documents a council will expect with each application.

Read article →
Which Reports Do I Need7 min read

Which reports a dark kitchen needs for planning

Dark kitchens are decided on odour and rider management. Here is the document pack, and why the use class is less settled than operators assume.

Read article →
Which Reports Do I Need7 min read

Report bundle for a bin and cycle store on flats

Blocks of flats have no householder permitted development rights, so a refuse or cycle store needs an application. Here is the evidence it turns on.

Read article →
Which Reports Do I Need7 min read

Documents for a heat pump on a block of flats

Class G covers blocks of flats as well as houses, but not a communal array. Here is where the right stops and what a planning submission needs instead.

Read article →
Which Reports Do I Need7 min read

Which reports a micro-brewery in an industrial unit needs

Breweries get refused on odour and plant noise, and the taproom decides the use class. Here is the document pack a micro-brewery fit-out usually needs.

Read article →