Which Reports Do I Need

When flood zone 2 meets a conservation area

7 min readBy PlanScope Editorial Team

Raised floor levels, impermeable renders and external bunds are the standard answers to flood risk and the ones a conservation officer resists. Here is how to resolve both evidence bases in one submission.

A site in Flood Zone 2 inside a conservation area needs a flood risk evidence base and a heritage evidence base that have to agree with each other, because the standard flood mitigation measures (raising finished floor levels, replacing historic fabric with impermeable materials, adding visible barriers and bunds) are the ones a conservation officer is most likely to resist. The combination is common in English market towns, where the oldest buildings sit closest to the river for reasons that made sense when the river powered the mill.

Flood Zone 2 means a medium probability of flooding, between a 1 in 100 and 1 in 1,000 annual chance from rivers and between 1 in 200 and 1 in 1,000 from the sea, before climate change allowances are applied. Any development proposal in Zone 2 needs a Flood Risk Assessment. Any proposal affecting the character or appearance of a conservation area engages the duty in section 72 of the Planning (Listed Buildings and Conservation Areas) Act 1990.

Why the two requirements pull in opposite directions

Flood risk management wants water kept out of habitable space, or let in and let out again without lasting damage. Heritage policy wants significance conserved, which on a riverside site often means keeping solid floors, lime plasters, soft bricks and a ground floor at the level it has occupied for two centuries.

The friction shows up in four places: floor levels, materials, external works and escape. A scheme that resolves all four on paper before submission tends to get a single round of consultation. A scheme that resolves none of them gets a holding objection from the lead local flood authority and a separate one from the conservation officer, pointing in different directions.

Raised floor levels against historic floor structures

Raising finished floor levels is the default answer to flood risk, and in a new build it costs nothing in heritage terms. In a conversion or extension of a historic building it can cost a great deal. Raising the floor changes the proportion of the room, cuts into window reveals, buries skirtings and plinths, and sometimes removes the original floor structure altogether.

Where the building is undesignated but contributes to the character of the area, the usual compromise is to raise levels in the new element only and leave the historic floor as it is. Where the historic floor has to come up, the heritage case has to explain what is being lost, why there is no alternative and how the loss is reduced. That reasoning belongs in a Heritage Statement alongside the proportionate assessment of significance, not buried in the flood chapter.

A useful intermediate position is to accept water entry at ground level and locate everything vulnerable above it. Services, consumer units, sockets, boilers and stored goods move up. Sleeping accommodation goes to the first floor. The ground floor becomes a space designed to be flooded and dried.

Resistance and resilience measures that work in heritage terms

Resistance keeps water out. Resilience accepts entry and limits the damage. Historic England's guidance on flooding and historic buildings leans towards resilience for traditionally built structures, because traditional construction is breathable and the measures that make it watertight often trap moisture and cause slower, worse decay.

Measures that tend to be acceptable:

  • Demountable or temporary barriers to doorways and low openings, stored on site and deployed on a flood warning
  • Non-return valves on drainage and sealed inspection chambers
  • Lime plasters and renders that can dry out, rather than cement render or gypsum
  • Breathable insulation and timber skirtings fixed so they can be removed and replaced
  • Raised electrical circuits with a dedicated ground floor ring that can be isolated
  • Flood doors matched to the original joinery profile in a reversible fitting

Measures that tend to meet resistance: continuous external bunds across a historic frontage, permanent flood gates in a boundary wall of interest, cement based waterproof renders on soft brick or stone, and injected damp proof courses that change how the wall behaves.

The reversibility test is the one that settles most arguments. A measure that can be removed in fifty years without leaving a mark is easier to justify than a permanent intervention of the same effectiveness.

Sequential and exception test implications

The sequential test asks whether the development could go somewhere at lower flood risk. Planning Practice Guidance on flood risk and coastal change exempts householder development, minor development and most changes of use from it, which covers a large share of conservation area work. Where it does apply, the area of search has to be agreed with the local planning authority, and a heritage asset in need of a viable use is a material consideration in defining that area.

The exception test is narrower than people expect in Zone 2. Under the flood risk vulnerability classification it is triggered in Zone 2 only for highly vulnerable development, which includes basement dwellings and some emergency services uses. More vulnerable development, including ordinary housing, is appropriate in Zone 2 without the exception test. A Sequential Test and an exception test are separate documents and the second is needed far less often than the first.

Where the building is listed, the heritage dimension of the sequential test argument grows teeth. Keeping a listed building in use is a public benefit, and the conservation of a designated asset carries great weight under national policy.

Who the consultees are and how to reconcile them

Body What it looks at Trigger
Environment Agency Main river flood risk, Zone 3 and some Zone 2 cases, finished floor levels Statutory consultee for development in Zone 2 and 3
Lead local flood authority Surface water, drainage design, SuDS Major development, and locally for others
Conservation officer Significance, character and appearance, materials Conservation area and listed building work
Historic England Grade I and II* buildings, scheduled monuments, some larger cases Thresholds set in the consultation direction
Sewerage undertaker Foul and combined sewer capacity, non-return valves Connection and capacity questions

The practical trick is to pre-empt the contradiction rather than let two consultees find it. One short section in the design statement, setting out the flood strategy and the heritage reasoning as a single argument, saves a round of correspondence. Pre-application advice that puts the flood officer and the conservation officer in the same conversation is worth the fee on this kind of site.

Drawings that satisfy both officers

Officers reconcile conflicting advice from drawings, not from text. The set that tends to work includes a section through the affected rooms showing existing and proposed floor levels against the design flood level, an elevation showing any barrier or flood door in place and removed, a materials schedule distinguishing retained historic fabric from new work, and a drainage layout with levels and non-return valve positions marked.

Add a flood response plan as an annex. It is short, it tells the officer who acts on a warning and what they do, and it answers the safety question that otherwise sits unresolved in the flood chapter.

The document set to submit

For a conservation area scheme in Flood Zone 2, expect to need a Planning Statement, a heritage statement with a proportionate assessment of significance, a flood risk assessment with the resistance and resilience strategy, and a Drainage Strategy where surface water arrangements change. A design and access statement is required for most development in a conservation area. A sequential test is needed where the proposal is not exempt, and an exception test only where the vulnerability classification demands it.

PlanScope can draft the policy framing and the structure of each of those documents from a postcode and a set of answers, with a "to be confirmed" flag wherever the flood levels, the survey data or the significance assessment need site evidence. Reports should be reviewed before submission and PlanScope does not guarantee planning approval. This is general guidance, not legal advice. Check the position with your local planning authority or a qualified professional before relying on it.

Frequently asked questions

Do I need a flood risk assessment in Flood Zone 2?

Yes. A site-specific flood risk assessment is expected for development proposals in Flood Zone 2 and Flood Zone 3, and for sites of one hectare or more anywhere, including Zone 1. Check the Environment Agency Flood Map for Planning for the zone, then confirm the scope and the climate change allowances with the local planning authority or the lead local flood authority.

Does the sequential test apply to a conservation area extension?

Usually not. Planning Practice Guidance on flood risk exempts householder development, minor development and most changes of use from the sequential test. Larger proposals in Flood Zone 2 do need it, and the area of search should be agreed with the council. Keeping a designated heritage asset in viable use is relevant to how that search area is defined.

Can I raise the floor level in a historic building for flood resilience?

Sometimes, but it has to be justified. Raising a floor changes room proportions, window reveals and skirting lines, and may remove original floor structure. Where the building is listed or contributes to the character of a conservation area, the heritage statement must explain the loss, why there is no alternative and how the harm is reduced.

Which flood measures do conservation officers normally accept?

Reversible ones. Demountable door barriers, non-return valves, lime plasters and renders that allow the wall to dry, breathable insulation, removable timber skirtings and raised electrical circuits are generally acceptable. Permanent bunds across a historic frontage and cement based waterproof renders on soft brick or stone usually are not.

Is an exception test needed in Flood Zone 2?

Only for highly vulnerable development under the flood risk vulnerability classification, which includes basement dwellings. Ordinary housing is classed as more vulnerable and is appropriate in Zone 2 without the exception test. The sequential test and the exception test are separate documents and the second is needed far less often.

Sources and further reading

flood riskconservation areaheritageflood zone 2resiliencewhich reports

This article is general guidance about the planning system in England and, where stated, the rest of the UK. It is not legal or professional advice. Check your local planning authority’s validation requirements and take professional advice for your specific site.

More in Which Reports Do I Need

View all →
Which Reports Do I Need7 min read

Which reports a dental or medical surgery change of use needs

A dental or medical surgery sits within Class E(e), which means the change of use is often not development at all. The documents that matter are the ones about parking turnover, plant noise and waste storage.

Read article →
Which Reports Do I Need7 min read

Shop front replacement: which consents and reports you need

Replacing a shop front and its signage normally runs through two separate consent regimes at once. This explains which one catches what, where deemed consent runs out, and the documents a council will expect with each application.

Read article →
Which Reports Do I Need7 min read

Which reports a dark kitchen needs for planning

Dark kitchens are decided on odour and rider management. Here is the document pack, and why the use class is less settled than operators assume.

Read article →
Which Reports Do I Need7 min read

Report bundle for a bin and cycle store on flats

Blocks of flats have no householder permitted development rights, so a refuse or cycle store needs an application. Here is the evidence it turns on.

Read article →
Which Reports Do I Need7 min read

Documents for a heat pump on a block of flats

Class G covers blocks of flats as well as houses, but not a communal array. Here is where the right stops and what a planning submission needs instead.

Read article →
Which Reports Do I Need7 min read

Which reports a micro-brewery in an industrial unit needs

Breweries get refused on odour and plant noise, and the taproom decides the use class. Here is the document pack a micro-brewery fit-out usually needs.

Read article →