A sandwich shop moving into hot food and extraction

7 min readBy PlanScope Editorial Team

Adding hot food may or may not be a change of use. The Class E boundary, the extraction design that councils accept, and the evidence a lawfulness certificate needs.

A sandwich shop that starts toasting paninis has probably not changed its planning use. A sandwich shop that puts in a griddle and sells hot bacon rolls to a queue of people who eat them in the street almost certainly has. The dividing line for a sandwich shop moving into hot food is not whether heat is applied: it is whether the hot food is mostly consumed on the premises or taken away.

Get that wrong and you are operating a sui generis use without permission, with an extraction system nobody has approved.

Where the use class line falls

Under the Use Classes Order 1987 as amended in 2020, Class E(a) covers the display or retail sale of goods other than hot food, and Class E(b) covers the sale of food and drink mostly consumed on the premises. The sale of hot food principally for consumption off the premises sits outside the classes altogether as a sui generis use.

That produces three positions.

What you sell Class Permission needed
Cold sandwiches and drinks to take away E(a) No change
Hot and cold food eaten mostly at tables in the shop E(b) None, movement within Class E
Hot food mostly taken away Sui generis Yes, change of use

Movement within Class E is not development, so a cold sandwich shop becoming a small cafe with seating is a commercial decision rather than a planning application. There is no general permitted development right running the other way into a hot food takeaway, so that direction needs an application. Check the current General Permitted Development Order for the rights that exist in the opposite direction, and check whether an article 4 direction applies locally, because many authorities have removed rights in shopping frontages.

The test is about the balance of trade and the physical arrangement rather than the menu. Seating capacity, counter layout, whether food is packaged for carrying, and the proportion of takings from hot food are the things an enforcement officer will look at.

What triggers an extraction requirement

Extraction becomes a planning issue when two things coincide: cooking that generates odour, and a receptor close enough to smell it.

Toasting a sandwich in a contact grill behind the counter rarely needs a dedicated extract. Frying, chargrilling, griddling bacon or cooking with oil at temperature does, and in a terraced parade with flats above it needs a properly designed system.

The physical works are usually what needs permission even where the use does not change. An external duct, a flue above the eaves, or a new louvre in a rear elevation is an alteration to the building, and on a listed building it needs listed building consent as well. A Ventilation and Extraction Statement setting out the cooking types, extract volume, filtration and discharge point is what councils ask for.

Building Regulations apply in parallel on ventilation rates and fire protection where a duct passes through other occupancies, and compliance with one does not satisfy the other.

Cooking types and their odour load

Published guidance on commercial kitchen exhaust systems grades odour risk by cooking process, and the required level of odour control follows from that risk and the distance to the nearest sensitive receptor.

In broad terms, chargrilling and deep frying sit at the high end, pan frying and griddling in the middle, and baking, boiling and reheating at the low end. The practical consequence is a filtration train: grease filters as a minimum, then odour control by carbon filtration, electrostatic precipitation or ultraviolet treatment where the risk and the receptor distance require it.

Two points applicants underestimate. Filtration needs maintenance, and a system with exhausted carbon performs like a system with none, so the maintenance regime is worth offering as a condition rather than resisting. And an Odour Assessment is sometimes needed in addition to the extraction statement where the receptor is very close or there is a history of complaints.

Fan noise is a separate question again. Extract fans run through the trading day and a Noise Impact Assessment may be required where windows of flats above or behind are affected.

Duct feasibility on the existing building

This is where schemes fail, and it is worth checking before you buy the equipment.

The conventional answer is a vertical duct on the rear elevation terminating at least a metre above the ridge or the highest point of the roof, so the plume disperses above the building rather than at window level. Four obstacles come up repeatedly:

  1. The flats above are in separate ownership, so the duct route needs the freeholder's consent and may need a wayleave.
  2. A duct passing through other occupancies has to be fire protected, which increases its size and cost.
  3. On a rear elevation facing a conservation area or a listed building, the visual impact of a 9m stainless duct is a planning objection in itself.
  4. Structural fixing to a Victorian rear wall sometimes needs strengthening that was not in the budget.

Where a full height duct is impossible, the fallback is a high specification filtration system discharging at low level. Councils are cautious about it, and the case has to be made with a design that shows the plume velocity, the discharge direction and the distance to the nearest opening window.

Illustrative example: a mid-terrace unit with two flats above in separate ownership. A rear duct to ridge height was refused by the freeholder, so the scheme used a three-stage system with grease filtration, electrostatic precipitation and carbon, discharging at first floor level away from the flats, with a maintenance schedule offered as a condition. Whether that is acceptable turns entirely on the local situation and the environmental health officer's view.

Hours, seating and consumption off the premises

The use class question and the hours question are linked, because a shop that stays open into the evening looks more like a takeaway whatever its daytime trade.

Where you are applying for a change of use, expect conditions on opening hours, on the number of covers, and sometimes on the proportion of the floor area given to seating. Where you are not applying, be careful about drifting: removing the tables to fit more display chillers can change the character of the use without any building work at all.

A late night refreshment licence is needed to sell hot food or drink to the public between 23:00 and 05:00, and that is a separate regime from planning. A licence does not authorise a planning use, and planning permission does not authorise late trading. The related note on cold food takeaways and Class E deals with the classification question in more detail.

Regularising an unauthorised change

If hot food has been sold for years without permission, there are two routes and they lead to different places.

A retrospective planning application puts the question to the authority on its merits, and the authority can refuse it. An application for a certificate of lawful existing use asks whether the use has become immune from enforcement through the passage of time, which for most breaches of planning control is a ten year period. The Levelling-up and Regeneration Act 2023 moves the remaining shorter periods to ten years, and the date that change takes effect should be checked at the time.

A Lawful Development Certificate is the only formal way to confirm that a use is lawful. Evidence is everything: dated invoices for cooking equipment, menus, supplier accounts, photographs, staff statements and accounts showing the split between hot and cold sales.

Enter your postcode on PlanScope to see which of the 66 report types a change of use of this kind is likely to need.

This is general guidance, not legal advice; check the position with your local planning authority or a qualified professional before relying on it. PlanScope provides AI-assisted draft reports for planning applications. Reports should be reviewed before submission. We do not guarantee planning approval.

Frequently asked questions

Does toasting sandwiches change my planning use?

Usually not. Class E(b) covers the sale of food and drink mostly consumed on the premises, so a shop with seating that heats food for customers eating in stays within Class E. Selling hot food principally for consumption off the premises is a sui generis use and needs planning permission.

How is the on or off premises test applied?

On the balance of trade and the physical arrangement rather than the menu. Seating capacity, counter layout, whether food is packaged for carrying and the proportion of takings from hot food are what an enforcement officer examines. Removing tables to fit chillers can change the character without any building work.

Do I need permission for the extract duct?

Usually yes, because an external duct, a flue above the eaves or a new louvre is an alteration to the building even where the use is unchanged. On a listed building you also need listed building consent. Building Regulations apply separately to ventilation rates and to fire protection where ducts cross other occupancies.

How high does the duct have to go?

The conventional design terminates at least a metre above the ridge or the highest point of the roof, so the plume disperses above the building rather than at window level. Where that is impossible, a high specification filtration system discharging at low level can be argued, with plume velocity and discharge direction shown.

What filtration will the council expect?

It follows the odour risk of the cooking process and the distance to the nearest sensitive receptor. Grease filtration is the minimum, with carbon, electrostatic precipitation or ultraviolet treatment added as the risk rises. Offer a maintenance regime as a condition, because exhausted carbon performs like no carbon at all.

Can I regularise years of unauthorised hot food sales?

Either by a retrospective application, which the authority can refuse, or by applying for a certificate of lawful existing use based on immunity through the passage of time, which for most breaches is ten years. Evidence matters: dated equipment invoices, menus, supplier accounts and accounts showing the hot and cold split.

Sources and further reading

hot food takeawayclass echange of useextractionodoursui generis

This article is general guidance about the planning system in England and, where stated, the rest of the UK. It is not legal or professional advice. Check your local planning authority’s validation requirements and take professional advice for your specific site.

More in Commercial Occupiers

View all →
Commercial Occupiers6 min read

A pet crematorium and the environmental permit

Animal cremation sits outside the use classes, needs an environmental permit as well as planning permission, and is normally decided on stack height, odour and the visitor element.

Read article →
Commercial Occupiers6 min read

A seasonal food kiosk on private land: the planning rules

Part 4 of the GPDO allows temporary use of land for 28 days a year, including a moveable kiosk. The curtilage exclusion, the day count across the planning unit and any hardstanding or services decide whether you need to apply.

Read article →
Commercial Occupiers6 min read

Reopening a nightclub after years of closure

A sui generis nightclub use does not lapse through non-use alone, but it can be abandoned. Physical condition, length of closure, intervening use and the owner's intentions decide it, and a certificate of lawfulness settles it.

Read article →
Commercial Occupiers6 min read

Betting shops, sui generis use and the change of use case

Betting offices left Class A2 in 2015 and never joined Class E, so a full application is always needed. Frontage clustering policy, shopfront design and the gambling premises licence decide the outcome.

Read article →
Commercial Occupiers7 min read

A cold store added to a food unit and its plant noise

A cold store is quiet; its condensers are not. How BS 4142 character corrections work against a low night background, and the mitigation that actually helps.

Read article →
Commercial Occupiers6 min read

An MOT bay added to an existing repair garage

An MOT bay in an existing garage keeps the same use class. The planning questions are the building works, the waiting vehicles and the noise of the test equipment.

Read article →