Report Deep Dives

The sequential test section of a flood submission

7 min readBy PlanScope Editorial Team

The area of search and the list of reasonably available sites decide whether a sequential test survives review. Land ownership is not a filter.

The sequential test asks one question: could this development go somewhere at lower flood risk? Everything in the section flows from that, and the two parts authorities reject most often are the area of search and the list of sites considered within it. A test that searches only the applicant's own land, or only the immediate neighbourhood of the application site, will be returned. So will one that dismisses alternative sites for reasons that have nothing to do with flood risk.

The test comes before design. A scheme can be perfectly safe, dry and resilient and still fail, because the sequential test is about location rather than mitigation.

What the sequential test asks

National policy directs development away from areas at highest risk of flooding. In application terms, the burden sits with the applicant to show there are no reasonably available sites appropriate for the proposed development in areas with a lower probability of flooding.

Several exemptions apply. Planning Practice Guidance confirms the test is not required for minor development, for most changes of use, or for individual proposals on sites already allocated in a development plan where the test was applied at plan-making stage. Change of use to a caravan, camping, chalet or park home site is treated differently, because of the vulnerability of the occupants.

Check which flood sources you are dealing with as well. The requirement has been extended beyond rivers and the sea towards all sources of flooding, including surface water, so confirm the current policy wording and the relevant policy reference in the National Planning Policy Framework before writing the section.

Defining the area of search and justifying it

The area of search is the first thing a reviewer looks at, and getting it wrong invalidates everything after it.

Planning Practice Guidance ties the area to the nature of the development and the need it meets. For general housing that is normally the local planning authority's administrative area, because housing need is assessed at that level. For a development meeting a catchment-wide need, such as a secondary school or a sports facility, the search area follows the catchment. For a use serving a single settlement, a smaller area can be justified, with the justification stated.

Agree it in writing at pre-application. A test built on an area the council later rejects is wasted work, and the officer will not simply substitute their own area for yours.

Set out in the section:

  • The area adopted and the policy or evidence basis for it
  • The development type and the need it addresses
  • Who agreed the area and when, with the correspondence referenced
  • The date of the search, because site availability changes

Identifying reasonably available sites

A reasonably available site is one in a suitable location for the type of development proposed, with a reasonable prospect of being available at the point in time envisaged. That definition does two things: it filters on suitability and timing, and it says nothing at all about who owns the land.

Use documented sources so the search can be repeated by someone else:

  1. The strategic housing and economic land availability assessment for the authority
  2. Local plan allocations and the policies map
  3. The brownfield land register
  4. Sites with extant permission that have not been implemented
  5. Call for sites submissions where published
  6. Commercial agents' listings for the relevant use and date range
  7. Any site the council or an objector has already suggested

Record every site considered, with its reference, area, flood zone and the reason it was excluded. A table is the only sensible format. Reviewers want to count the sites, not read a narrative about them.

Why the applicant's land interest is not a filter

This is the most common fatal flaw. The guidance is explicit that availability is not limited to land in the applicant's ownership or control, so the argument "we only own this site" carries no weight whatsoever in the test.

Nor do these:

  • The alternative site is more expensive
  • The alternative site would deliver fewer units or a lower return
  • The applicant has already invested in design work on this site
  • The alternative site is in another ownership and might not be sold

Legitimate reasons for excluding a site are about suitability and timing. A site too small for the proposed use, in the wrong location for the need, constrained by a designation that cannot be overcome, already permitted for something else, or not available within the relevant period. State which of those applies to each site and why.

One honest point: this is the part of the test applicants find hardest to accept, and it is the part inspectors apply most strictly on appeal.

When the test is passed

The test is passed when the evidence shows no reasonably available site at lower flood risk could accommodate the development. That conclusion has to be reached on the evidence presented rather than asserted in a closing paragraph.

A well-structured conclusion states the area of search, the number of sites identified, the number screened out and on what grounds, and the position of the application site in the resulting hierarchy. Where a site at lower risk does exist but is unsuitable for a specific reason, name the site and the reason rather than leaving it in the discarded column.

Where the test is passed, say so in one sentence and move on. Where it cannot be passed honestly, the answer is usually a different site rather than a longer section.

Moving on to the exception test

Passing the Sequential Test does not get a more vulnerable use into Flood Zone 3a on its own. The flood risk vulnerability classification in Planning Practice Guidance sets out which uses are compatible with which zones, and where a use is shown as acceptable only subject to the exception test, both parts of that test then apply: wider sustainability benefits to the community that outweigh the flood risk, and a demonstration that the development will be safe for its lifetime without increasing flood risk elsewhere.

The second limb depends on the Exception Test evidence, including finished floor levels, climate change allowances and safe access and egress. Reviewers read the sequential and exception sections together, so a figure quoted in one has to match the other.

Keep the two tests structurally separate inside the Flood Risk Assessment. Merging them into a single chapter is a reliable way to make an officer think neither has been done properly.

What a reviewer checks, in order

The sequence is predictable. The area of search and its justification. Whether an exemption was claimed and whether it applies. The sources searched and the search date. The site table and the exclusion reasons. Any mention of ownership as a reason. The flood zone of the application site against the vulnerability classification. Then the conclusion.

Illustrative example: a 24-dwelling scheme in Flood Zone 2 on the edge of a market town. The area of search is the district, agreed by email with the case officer. Thirty-one sites are identified from the land availability assessment and the brownfield register, of which 19 are in Flood Zone 1. Of those 19, eleven are below 0.3 hectares and cannot take 24 dwellings, five are allocated for employment use, two are in a conservation area with capacity for fewer than ten homes, and one is available and suitable. On that evidence the test is not passed, and the honest advice is to pursue the available site. This example is illustrative only.

That outcome is the point of the exercise. A sequential test written to justify a decision already taken reads exactly like one, and consultees have seen hundreds.

Browse all 66 PlanScope report types and start a draft at PlanScope. The draft structures your sequential test to national guidance and flags the facts it cannot verify, and a flood risk specialist should review it before submission.

This is general guidance, not legal advice. Check the position with your local planning authority or a qualified professional before relying on it. PlanScope provides AI-assisted draft reports for planning applications. Reports should be reviewed before submission. We do not guarantee planning approval.

Frequently asked questions

What area should the sequential test search cover?

Planning Practice Guidance ties it to the development type and the need being met. For general housing that is normally the local planning authority's administrative area. For a facility serving a wider catchment, the catchment applies. Agree the area in writing at pre-application stage, because a rejected area of search invalidates the whole exercise.

Does the sequential test apply to minor development?

No. Planning Practice Guidance confirms it is not required for minor development, for most changes of use, or for individual proposals on sites allocated in a development plan where the test was applied at plan-making stage. Change of use to a caravan, camping, chalet or park home site is treated differently because of occupant vulnerability.

Can I exclude a site because I do not own it?

No. Availability is not limited to land in the applicant's ownership or control, and an argument based on ownership carries no weight. Legitimate exclusions relate to suitability and timing: the site is too small for the proposed use, wrongly located for the need, constrained, already committed, or unavailable within the relevant period.

How should alternative sites be presented?

In a table listing every site considered, with its reference, area, flood zone and the specific reason for exclusion, plus the sources searched and the date of the search. Reviewers want to count sites and check the reasoning, and a narrative description of the search is far harder to audit than a table.

Does passing the sequential test allow development in Flood Zone 3?

Not by itself. The flood risk vulnerability classification sets out which uses are compatible with which zones, and where a use is acceptable only subject to the exception test, both limbs of that test apply: wider sustainability benefits, and a demonstration that the development is safe for its lifetime without increasing flood risk elsewhere.

Does the test cover surface water flooding?

The requirement has been extended beyond rivers and the sea towards all sources of flood risk, including surface water. Confirm the current wording and the policy reference in the National Planning Policy Framework before writing the section, because the Framework was reissued in August 2026 with policy-coded chapters.

Sources and further reading

sequential testflood risk assessmentexception testflood zonesplanning policy

This article is general guidance about the planning system in England and, where stated, the rest of the UK. It is not legal or professional advice. Check your local planning authority’s validation requirements and take professional advice for your specific site.

More in Report Deep Dives

View all →
Report Deep Dives7 min read

The maintenance section of a landscape strategy

The maintenance section is where a landscape strategy is won or lost. It has to name who does the work, for how long, paid from what, with what happens when planting fails.

Read article →
Report Deep Dives7 min read

The viability appraisal inputs section explained

A reviewer reads the land value derivation and the developer return first. How to set out every input with its source, and test the conclusion honestly.

Read article →
Report Deep Dives7 min read

The mitigation section of a protected species survey

Officers read the mitigation section asking whether the measures can be conditioned and whether a licence is likely. How to write one that answers both.

Read article →
Report Deep Dives7 min read

The root protection area section of a tree survey

The root protection area is calculated as 12 times stem diameter and capped at 707 square metres. Everything in the arboricultural submission follows from that figure.

Read article →
Report Deep Dives7 min read

The significance of effects section of an EIA chapter

Matrices do not do the thinking. Here is how to write a significance section a decision maker can follow and a reviewer can test, chapter by chapter.

Read article →
Report Deep Dives7 min read

Waste streams and recovery rates in a waste plan

Recovery and diversion are different numbers. Forecast by activity, name the destinations, and build the reporting format in before work starts.

Read article →