Permitted development rights say nothing about drains. If a public sewer runs under the garden, the water company has a separate say, and foundations are the expensive part.

An extension over a public sewer needs the agreement of the water and sewerage undertaker, and that is entirely separate from planning. A rear extension can be permitted development under Class A of the General Permitted Development Order 2015, need no planning application at all, and still be unbuildable until the undertaker agrees to it. The same applies to anything within three metres of a public sewer. Since the transfer of private sewers in October 2011, most shared drains serving more than one property became public, so a great many ordinary suburban back gardens now have a public sewer running across them.

Why planning rights do not resolve the sewer

Permitted development is a planning concept. It removes the need for a planning application and says nothing about building regulations, party walls, covenants, or drainage.

The sewer requirement comes from a different place. Part H of the Building Regulations deals with drainage, and the relevant section covers building over or near a public sewer. Approval under the Building Regulations depends on the undertaker's position, so building control will not sign off work that the undertaker has not agreed.

The undertaker also has statutory powers of access to its apparatus. A structure that prevents maintenance of a sewer can be removed, and the cost falls on the owner. That remains true however legitimate the extension was in planning terms.

So the sequence is: establish the drainage position first, then design, then deal with planning if it is needed.

Finding the sewer before you design

Two sources. The undertaker publishes a sewer map, and a copy of the relevant extract can be bought for a modest fee, usually as part of a drainage and water enquiry. The second source is the ground: lift the manhole covers in and around the garden, look at the direction of flow, and count the connections.

The map is not complete. Lateral drains that transferred into public ownership are often not shown, and a pipe serving two or more properties is very likely to be public even where it appears nowhere on the record. If a neighbour's waste passes under your garden, treat the pipe as public until the undertaker says otherwise.

Measure the depth at the nearest manholes and work out the invert level and the gradient. That tells your designer whether the foundation problem is manageable or serious before any drawings are produced. Checking the public record and then verifying it on site is the same discipline described in checking planning data sources before relying on a right.

A drain camera survey is worth the money on an older property. A collapsed or displaced pipe under a proposed extension is far cheaper to find now than after the slab is poured.

The build over or build near agreement

Undertakers operate two routes. For straightforward cases, many offer a simple notification or self-certification process. For anything else, a full build over agreement is needed, which is a formal consent with conditions attached.

The criteria vary between companies, and the published requirements of your own undertaker are the ones that matter. Conditions commonly encountered include a prohibition on building over a manhole, a limit on the length of pipe that may be covered, a requirement for the pipe to be in sound condition evidenced by a camera survey, minimum clearances between the foundation and the pipe, and a requirement to maintain access for maintenance.

Manholes are the usual sticking point. Building over an inspection chamber is normally refused outright, and the answer is either to redesign the extension around it or to relocate the chamber, which is a drainage alteration in its own right.

Allow time. A simple notification can turn round in a few weeks. A full agreement on a deeper or larger sewer takes longer, and the undertaker may require its own engineer to review the foundation design.

Diversion and who pays

Where the extension cannot work around the sewer, the pipe can be diverted. The Water Industry Act 1991 provides for a sewer to be diverted at the request of an owner or occupier, and the undertaker carries out or approves the work.

The applicant pays, and the figures are substantial compared with a build over agreement. Beyond the pipework itself, the cost includes design, any road or footway works, traffic management where the new line crosses a highway, and reinstatement. On a tight urban plot a diversion can cost more than the extension.

Get a budget figure before committing to a layout that needs one. Undertakers will provide an estimate on application, and the estimate is the number to put into the project budget rather than a contractor's guess.

Where a diversion is unavoidable, consider whether a smaller extension that clears the easement produces a better result overall.

Foundation design near a sewer

The principle in the Building Regulations guidance is to make sure the building load does not bear on the pipe and that future excavation to repair the pipe does not undermine the building.

Where the extension is within one metre of the pipe, the foundation is normally taken down at least to the invert level of the sewer. Beyond one metre, the foundation is taken below a line drawn upwards at 45 degrees from the invert, so the deeper the pipe, the deeper the foundation.

For a sewer at two metres depth close to the wall line, that means mass concrete to around two metres, which is a real cost and a confined space excavation. Alternatives include a reinforced concrete lintel bridging over the line of the pipe with the foundations either side, or a piled and beam solution. Each needs structural design.

Ask the structural engineer to price the options before the plans are finalised. A rear extension moved 600mm forward can halve the foundation cost, and that decision is free at sketch stage.

Building control and the undertaker

The two consents are linked but separate. Building control checks compliance with the Building Regulations, including drainage, and will want evidence that the undertaker has agreed before issuing a completion certificate.

Submit the build over application early and keep the correspondence. When the property is sold, the buyer's solicitor will ask for both the completion certificate and the build over agreement, and the absence of either delays the sale. Indemnity insurance is sometimes used as a substitute and is a poor one, because it insures against enforcement rather than against the sewer failing under the extension.

Where the extension needs planning permission as well, because it exceeds the Class A limits or because permitted development rights have been removed, the planning statement should mention the drainage position. The council will not determine the application on it, but a case officer who can see the point has been addressed will not ask about it later.

Sequencing the approvals

  1. Buy the sewer map extract and lift the covers on site.
  2. Commission a camera survey where the pipe is old or its condition is unknown.
  3. Design the extension to avoid manholes and to minimise the length of pipe covered.
  4. Confirm the planning route, whether permitted development, a certificate of lawfulness, or a householder application.
  5. Submit the build over notification or agreement application to the undertaker.
  6. Submit the building regulations application, with the foundation design responding to the pipe depth.
  7. Keep the agreement, the completion certificate and the survey together in the property file.

Where an outbuilding is being added at the same time, both structures need checking against the sewer line, and the interaction between the two projects is covered in combining an extension and an outbuilding in one project.

This is general guidance, not legal advice. Check the position with your local planning authority or a qualified professional before relying on it. A Lawful Development Certificate is the only formal way to confirm that works are lawful in planning terms, and it does not address the drainage position at all.

PlanScope provides AI-assisted draft reports for planning applications. Reports should be reviewed before submission. We do not guarantee planning approval.

Frequently asked questions

Does permitted development mean I can build over a sewer?

No. Permitted development removes the need for a planning application and has no effect on drainage. Where the extension sits over or within three metres of a public sewer, the water and sewerage undertaker's agreement is needed separately, and building control will not issue a completion certificate without it.

How do I find out if there is a public sewer in my garden?

Buy a sewer map extract from your undertaker, usually through a drainage and water enquiry, then lift the manhole covers and check the direction of flow and the number of connections. Shared drains serving more than one property transferred into public ownership in October 2011 and are often missing from the map.

What does a build over agreement cost?

Undertakers publish their own fees and the charge for a straightforward agreement is modest compared with the construction. The real costs sit elsewhere: the camera survey, deeper or bridged foundations, and relocating an inspection chamber. A full sewer diversion is in a different order of magnitude again.

How deep do foundations need to be next to a sewer?

Where the extension is within one metre of the pipe, foundations are normally taken at least to the invert level of the sewer. Beyond one metre, they are taken below a line drawn upwards at 45 degrees from the invert. A deeper sewer therefore means deeper and more expensive foundations.

Can I build over a manhole?

Normally not. Undertakers almost always refuse consent to build over an inspection chamber because it removes access for maintenance. The options are to redesign the extension so the chamber sits outside the footprint, or to relocate the chamber as a separate drainage alteration agreed with the undertaker.

Sources and further reading

extensionspublic sewerbuild over agreementpermitted developmentbuilding controlhouseholder

This article is general guidance about the planning system in England and, where stated, the rest of the UK. It is not legal or professional advice. Check your local planning authority’s validation requirements and take professional advice for your specific site.

More in Permitted Development

View all →
Permitted Development7 min read

Enclosing a carport or open porch under Class A

Whether a carport infill is permitted development depends on where it sits relative to the principal elevation. Porches have their own class with more generous limits.

Read article →
Permitted Development7 min read

Adding a second extension when one already exists

Class A measures everything from the original dwellinghouse, so an extension built in 1998 has already used part of your allowance. How to work out what is left.

Read article →
Permitted Development7 min read

Extending a home created by a commercial conversion

A dwelling created by prior approval does not automatically arrive with householder permitted development rights. Flats have none, and the date tests run from when the building was built.

Read article →
Permitted Development9 min read

Permitted development where an earlier permission conditions the site

A rear extension can sit well within Class A and still be unlawful, because a condition on the permission that created the house says otherwise. How Article 3(4) works in practice.

Read article →
Permitted Development8 min read

Agricultural prior approval refused on siting or design

Under Part 6 the council can only refuse the siting, design and external appearance you proposed. The permitted development right survives, so a revised set of details usually beats an appeal.

Read article →
Permitted Development7 min read

Hard standing, plant and storage at an industrial unit

Part 7 of Schedule 2 covers hard surfaces, plant and private ways at industrial premises. Article 3(4) removes those rights where the original permission carries a condition, which is where most disputes begin.

Read article →