Permitted Development

Enclosing a carport or open porch under Class A

7 min readBy PlanScope Editorial Team

Whether a carport infill is permitted development depends on where it sits relative to the principal elevation. Porches have their own class with more generous limits.

Enclosing a carport is usually permitted development, and the thing that decides it is not the size of the carport. It is where the carport sits in relation to the front wall of the house. Infill a carport that tucks under the first floor, behind or flush with the principal elevation, and you are normally within Class A of Part 1 of Schedule 2 to the General Permitted Development Order 2015. Infill one that projects forward of that elevation towards a highway and you are outside it.

An open porch is a different question again, because porches have their own class with its own limits, and those limits are more generous than people expect.

Whether enclosing is an enlargement or an alteration

Class A permits the enlargement, improvement or other alteration of a dwellinghouse, so the distinction matters less than it first appears. Filling in the open sides of a carport with a wall, a door and a window is work affecting the external appearance of the building, so it is development, and it needs to fall within Class A to be permitted.

What matters are the limits Class A imposes. The ones that bear on a carport infill are:

  • whether the enlarged part extends beyond a wall forming the principal elevation and fronting a highway
  • whether it extends beyond a side wall where that wall fronts a highway
  • whether the height of the enlarged part exceeds the height of the highest part of the existing roof, or the eaves height exceeds the existing eaves
  • whether buildings in the curtilage other than the original house would then cover more than 50 per cent of the curtilage
  • whether the eaves are within 2 m of a boundary and above 3 m high

A carport infill rarely troubles the height limits, because you are working under an existing roof. It very often troubles the principal elevation limit.

Where the carport sits decides the answer

Three arrangements come up, and they give three different answers.

Arrangement Position Usual outcome
Integral carport under the first floor Within the original footprint, flush with or behind the front wall Normally permitted under Class A
Carport to the side, set back from the front wall Behind the principal elevation Normally permitted, subject to the side wall and boundary limits
Carport projecting forward of the front wall Beyond the principal elevation, fronting a highway Not permitted development, application needed

The second row carries a trap. Where the carport is to the side and the side wall itself fronts a highway, as on a corner plot, the restriction on extending beyond a side wall fronting a highway applies and the infill falls outside Class A.

Measure from the original wall rather than from what is there now. A house that already has a front porch or a bay added later does not get a new reference line, and the same cumulative logic applies here, so it is worth checking the planning data sources before relying on a right on a house that has already been extended.

And check the roof. Where the carport roof is a flat roof over an open structure, enclosing the space below sometimes means raising or rebuilding that roof to get adequate headroom and insulation, which can breach the eaves height limit where the structure is close to a boundary.

Porches have their own permitted development class

This is the part worth knowing before you commission a design. Class D of Part 1 permits the erection or construction of a porch outside any external door of a dwellinghouse, subject to three limits:

  1. the ground area, measured externally, must not exceed 3 m²
  2. no part may be more than 3 m above ground level
  3. no part may be within 2 m of any boundary of the curtilage of the dwellinghouse that fronts a highway

So enclosing a small open porch, where the finished structure stays within 3 m², stays under 3 m high and sits more than 2 m from the boundary with the road, is permitted under Class D even though it projects forward of the principal elevation. Class D is not caught by the principal elevation restriction that applies under Class A.

The 2 m boundary rule is the one that fails most often. On a terrace or a 1930s semi with a short front garden, the front boundary wall is frequently less than 2 m from where the porch would sit, and the project falls back to needing an application.

Two further points. The 3 m² is measured externally, so wall thickness counts. And if the enclosed structure is large enough to read as a room rather than a porch, the council may treat it as an extension under Class A rather than a porch under Class D, with the principal elevation test then applying.

Materials and the similar appearance condition

Class A carries a condition that the materials used in any exterior work must be of a similar appearance to those used in the construction of the exterior of the existing dwellinghouse.

Similar appearance is not identical, and it is not a licence either. The common failures on a carport infill are a brick that reads obviously different in colour or texture, a render panel where the rest of the house is brick, and a window frame in a material or colour that matches nothing else on the elevation. On a 1970s estate with a consistent brick, a mismatched infill is visible from the street and is exactly the sort of thing a neighbour reports.

Get a sample panel built before the main run. It costs a morning and resolves an argument that is otherwise permanent.

The parking condition people forget

This is where carport projects most often go wrong, and it has nothing to do with Class A.

Houses on estates built from the 1960s onwards frequently carry a condition on the original planning permission requiring the garage or carport to be retained and kept available for the parking of a motor vehicle. A condition in those terms survives everything. Permitted development rights do not override it, and enclosing the carport in breach of it is a breach of condition the council can enforce against.

So check the original permission for the house, not just the permitted development limits. Where such a condition exists, you need an application under section 73 of the Town and Country Planning Act 1990 to vary or remove it, and the council will consider whether the remaining parking provision is acceptable against its standards. In a controlled parking zone, or on a street with evident parking pressure, that is a real question rather than a formality.

Where no condition exists, the loss of a parking space is not a planning matter at all under permitted development.

Conservation areas and other designated land

On designated land, meaning conservation areas, National Parks, National Landscapes, the Broads and World Heritage Sites, Class A is narrowed. Cladding of any part of the exterior is taken out, and extensions beyond a side wall are not permitted at all, which removes the side carport option entirely.

Class D porches are not restricted in the same way on designated land, though the works may still affect the character of a conservation area in practice. An Article 4 direction can also withdraw householder rights altogether, and in that case a front infill of any kind needs an application. Our note on permitted development limits in a conservation area sets out what survives.

What to submit if an application is needed

A householder application needs existing and proposed floor plans and elevations, a location plan with the red line around the whole property, and a block plan showing the parking layout after the works.

Where parking is the issue, show where a car can still stand on the plot with dimensions, and show the turning if the access is tight. Where a condition has to be varied, make the section 73 application at the same time rather than in sequence.

A short Planning Statement dealing with the parking position, the materials and the effect on the street scene does more than a covering letter, particularly where the council has a householder design guide you can respond to directly. If a prior approval or householder application is refused, the routes are set out in prior approval refusals and the appeal route.

For certainty before building, apply for a certificate of lawfulness of proposed use or development under section 192 of the 1990 Act. Enter your postcode on PlanScope to see which documents a householder application for your property would need.

This is general guidance, not legal advice. A certificate of lawful development is the only formal way to confirm that works are lawful, so check the position with your local planning authority or a qualified professional before relying on it. PlanScope provides AI-assisted draft reports for planning applications. Reports should be reviewed before submission. We do not guarantee planning approval.

Frequently asked questions

Is enclosing a carport permitted development?

Usually yes, where the carport sits flush with or behind the wall forming the principal elevation. Class A does not permit an enlarged part that extends beyond a principal elevation fronting a highway, or beyond a side wall fronting a highway, so a carport projecting forward of the front wall needs a planning application.

What are the Class D limits for a porch?

The ground area measured externally must not exceed 3 m², no part may be more than 3 m above ground level, and no part may be within 2 m of any boundary of the curtilage that fronts a highway. Class D is not subject to the principal elevation restriction that applies under Class A.

Can a planning condition stop me enclosing my carport?

Yes, and this is the most common problem. Houses on estates built from the 1960s onwards often carry a condition requiring the garage or carport to be retained and kept available for parking a vehicle. Permitted development rights do not override it, so you need a section 73 application to vary or remove it.

Do the materials have to match the existing house?

Class A requires materials used in exterior work to be of a similar appearance to those used on the exterior of the existing dwellinghouse. Similar is not identical, but a render panel on a brick house or an obviously mismatched brick will fail. Build a sample panel before the main run.

What changes in a conservation area?

On designated land, cladding is taken out of Class A and extensions beyond a side wall are not permitted at all, which removes the side carport option. An Article 4 direction can withdraw householder rights entirely, in which case any front infill needs a planning application.

Sources and further reading

carportporchpermitted developmentclass aclass dhouseholder

This article is general guidance about the planning system in England and, where stated, the rest of the UK. It is not legal or professional advice. Check your local planning authority’s validation requirements and take professional advice for your specific site.

More in Permitted Development

View all →
Permitted Development7 min read

Adding a second extension when one already exists

Class A measures everything from the original dwellinghouse, so an extension built in 1998 has already used part of your allowance. How to work out what is left.

Read article →
Permitted Development7 min read

A householder extension built over a public sewer

Permitted development rights say nothing about drains. If a public sewer runs under the garden, the water company has a separate say, and foundations are the expensive part.

Read article →
Permitted Development7 min read

Extending a home created by a commercial conversion

A dwelling created by prior approval does not automatically arrive with householder permitted development rights. Flats have none, and the date tests run from when the building was built.

Read article →
Permitted Development9 min read

Permitted development where an earlier permission conditions the site

A rear extension can sit well within Class A and still be unlawful, because a condition on the permission that created the house says otherwise. How Article 3(4) works in practice.

Read article →
Permitted Development8 min read

Agricultural prior approval refused on siting or design

Under Part 6 the council can only refuse the siting, design and external appearance you proposed. The permitted development right survives, so a revised set of details usually beats an appeal.

Read article →
Permitted Development7 min read

Hard standing, plant and storage at an industrial unit

Part 7 of Schedule 2 covers hard surfaces, plant and private ways at industrial premises. Article 3(4) removes those rights where the original permission carries a condition, which is where most disputes begin.

Read article →