Fire, Structural and Basements articles – page 11

335 articles
Fire, Structural and Basements6 min read

Disproportionate collapse and building class in design

The consequence class a building falls into is fixed by storey count, use and floor area, all of which are settled at planning stage. What each class requires and where the thresholds bite.

Read article →
Fire, Structural and Basements6 min read

Dissolution features and shallow workings outside coalfields

Outside coalfield referral areas nothing prompts the ground stability question. Soluble rocks and non coal mine workings have to be identified by the applicant, through the desk study, geophysics and probing.

Read article →
Fire, Structural and Basements7 min read

Foundation design on made ground and former industrial sites

Fill varies over metres, not hundreds of metres. The design has to cope with that variation, and differential settlement is the failure it must prevent.

Read article →
Fire, Structural and Basements8 min read

Ground gas protection and BS 8485 measures

Protection design follows the characteristic situation, and that follows the monitoring data. Too few rounds in settled weather is where schemes lose a season.

Read article →
Fire, Structural and Basements7 min read

Underpinning a party wall under the 1996 Act

Section 2 covers underpinning a party structure and section 6 covers nearby excavation. The notice periods differ, and the sequence decides the programme.

Read article →
Fire, Structural and Basements7 min read

Fire strategy for a residential block above commercial units

Flats above shops means two fire strategies in one structure. Separate escape, a hard compartment boundary and coordinated risers decide the ground floor plan.

Read article →
Fire, Structural and Basements7 min read

Balconies, external walls and fire spread

A balcony attached to an external wall is a specified attachment under the Building Regulations. On relevant buildings that decides the decking, the soffit and the elevation.

Read article →
Fire, Structural and Basements7 min read

Smoke control in common corridors at planning stage

Smoke control in a block of flats decides corridor length, core size, roof plant and the elevation. The three strategies and what each one needs reserving at concept stage.

Read article →
Fire, Structural and Basements7 min read

Dry risers, wet risers and the height that separates them

Approved Document B puts dry rising mains above 18 metres and wet mains above 50 metres. The switch brings a water store, pumps and a plant room that a core drawn for a dry main cannot absorb.

Read article →
Fire, Structural and Basements7 min read

Firefighting shafts and what they take from the floor plate

Once a floor sits more than 18 metres above fire service access, the core gains a lobby, a lift and a smoke shaft with minimum dimensions that do not compress.

Read article →
Fire, Structural and Basements7 min read

Sprinklers in blocks of flats and the 11 metre trigger

Suppression in new blocks of flats is triggered at 11 metres in England. The 18 metre figure is the higher-risk building threshold, and the two are often confused.

Read article →
Fire, Structural and Basements6 min read

Second staircases above 18 metres and what changed

A consented single stair tower above 18 metres cannot be built as approved. How the requirement arrived, what it costs in floor area and which planning route to take.

Read article →
Fire, Structural and Basements6 min read

The golden thread and what planning contributes to it

Gateway One fire statements, approved drawings and discharged conditions all feed the golden thread. How to structure planning information so it survives handover.

Read article →
Fire, Structural and Basements6 min read

Gateway three and the completion certificate

Gateway three is an assessment of as-built evidence, not a final inspection. No completion certificate means no lawful occupation, no sales completions and no tenancy starts.

Read article →
Fire, Structural and Basements6 min read

What gateway two requires before construction starts

For a higher-risk building the Building Safety Regulator is the building control authority, and work cannot start until it has approved the design. That moves the design freeze months earlier.

Read article →
Fire, Structural and Basements6 min read

Basement flood risk: sumps, valves and safe egress

A basement used for sleeping is highly vulnerable development, which rules it out in Flood Zone 3 and triggers the Exception Test in Zone 2. Here is what the assessment has to cover.

Read article →
Fire, Structural and Basements6 min read

Fire safety in Class MA conversions to housing

A Class MA prior approval can be granted on a scheme that cannot lawfully be built, because fire safety sits outside the matters the council may consider.

Read article →
Fire, Structural and Basements6 min read

Demolition method statements and structural stability

The stability case is the part of a demolition method statement that gets rejected, and it belongs to the structural engineer rather than the contractor.

Read article →
Fire, Structural and Basements7 min read

Ground movement from piling next to existing buildings

Vibration that damages nothing still generates complaints. How piling method, damage categories and trigger levels are handled in a planning application.

Read article →
Fire, Structural and Basements7 min read

Eurocode 7 and geotechnical evidence for planning

Planning does not need a foundation design. It needs a ground model, a defensible investigation scope and mitigation that can be secured by condition.

Read article →
Fire, Structural and Basements7 min read

Facade retention: structural and heritage evidence

Retaining a frontage while rebuilding behind it needs an honest harm assessment and a temporary works scheme that fits the street. What to submit and why.

Read article →
Fire, Structural and Basements6 min read

Basement excavation and tree root protection areas

The root protection area usually covers the basement footprint. How encroachment is measured, which structural solutions buy retention, and what groundwater change does later.

Read article →
Fire, Structural and Basements6 min read

Basement works and householder permitted development

Class A can cover an underground enlargement, but the excavation and underpinning are often separate engineering operations. What that means for a house basement.

Read article →
Fire, Structural and Basements7 min read

Party wall matters that are not planning matters

Party wall obligations and planning permission are separate regimes. What the 1996 Act covers, why the council cannot enforce it, and when to serve notices.

Read article →