Fire, Structural and Basements articles – page 12

335 articles
Fire, Structural and Basements7 min read

Movement monitoring during basement construction

A monitoring condition rarely says what to measure or how accurately. Baseline readings, instrument selection and trigger levels tied to predicted movement are what make the scheme work.

Read article →
Fire, Structural and Basements7 min read

Basement waterproofing to BS 8102 and the design water table

BS 8102 waterproofing decisions follow from two things: the grade of internal environment the basement has to achieve, and how high groundwater can rise against the structure.

Read article →
Fire, Structural and Basements6 min read

What a Basement Impact Assessment has to cover

Screening, scoping, investigation then impact assessment, across land stability, groundwater and surface water. Skipping a stage is how these get refused.

Read article →
Fire, Structural and Basements6 min read

Evacuation lifts and inclusive escape in planning layouts

A refuge that eats the stair width is not a refuge. Inclusive escape has to be resolved while the core is still being drawn, not at Building Regulations stage.

Read article →
Fire, Structural and Basements6 min read

Fire service access and water supplies at planning stage

Approved Document B sets the geometry a fire appliance needs, and that geometry is a site layout constraint. Sorting it after permission costs units.

Read article →
Fire, Structural and Basements6 min read

Writing a Fire Statement: the sections and the evidence

A Fire Statement is a form completed by someone with fire engineering competence and supported by dimensioned drawings. Most inadequate ones fail on the drawings rather than the text.

Read article →
Fire, Structural and Basements6 min read

What the Building Safety Regulator checks at Gateway One

At Planning Gateway One the regulator comments as a statutory consultee rather than approving a design. Most of its requests are for dimensioned information that was missing from the drawings.

Read article →
Fire, Structural and Basements7 min read

Structural risk in a change of use application

Prior approval and planning permission say nothing about whether the frame can take the conversion. The structural questions decide unit count and headroom, so they belong at feasibility stage.

Read article →
Fire, Structural and Basements7 min read

Retaining existing structure rather than demolishing

Where a council applies a retrofit first expectation, the application turns on an options appraisal comparing retention and demolition on the same basis. The structural testing has to come first.

Read article →
Fire, Structural and Basements8 min read

Fire safety in listed and historic buildings

Approved Document B is one way of showing compliance, and on a historic building it is often the worst one. Start from the fire engineering objective rather than the standard solution.

Read article →
Fire, Structural and Basements8 min read

Mining legacy and the coalfield referral areas

Sites inside a Development High Risk Area need a coal mining risk assessment with the application. The check is free and takes minutes, and the permit to disturb coal is a separate consent.

Read article →
Fire, Structural and Basements6 min read

Structural justification for demolition in a conservation area

A report saying the building is in poor condition does not answer the statutory duty. What has to be shown is that repair is not a reasonable option, with evidence.

Read article →
Fire, Structural and Basements6 min read

Structural surveys for barn and church conversions

The structural report has one job: showing the building can take the new loads without substantial rebuilding. Trial pits and opening up are where those schemes are won.

Read article →
Fire, Structural and Basements6 min read

Basements and the Party Wall etc. Act alongside planning

Planning permission does not let you start digging. The Party Wall etc. Act runs separately, with its own notices, timescales and costs for a basement project.

Read article →
Fire, Structural and Basements6 min read

Ground movement assessment for a basement, explained

The ground movement section decides a basement application. Here is what the engineer models, how damage categories are assigned and what a monitoring regime should say.

Read article →
Fire, Structural and Basements6 min read

Basement impact assessment: the standard four stage structure

Boroughs that require a basement impact assessment expect the same four stage structure. Here is what belongs in each stage and where audits usually stall.

Read article →
Fire, Structural and Basements6 min read

Sprinklers and suppression: what planning can require

Approved Document B decides where sprinklers are needed. This sets out the narrow cases where a planning condition survives the six tests, and the space and water issues behind them.

Read article →
Fire, Structural and Basements6 min read

External wall materials and combustibility at planning

Planning controls appearance while Building Regulations decide what can be built. This is how to specify external wall materials on a tall residential scheme without creating a conflict.

Read article →
Fire, Structural and Basements6 min read

Fire appliance access in a residential site layout

Fire appliance access depends on a layout fixed at planning. Here are the dimensions that govern it, the hose distance rule, hydrant provision and the gate details that get missed.

Read article →
Fire, Structural and Basements6 min read

Relevant buildings: the 18 metre and seven storey test

A fire statement is required for relevant buildings at 18 metres or seven storeys. Here is where the datum sits, which storeys are excluded, and how podium schemes are treated.

Read article →
Fire, Structural and Basements6 min read

The Health and Safety Executive as a planning consultee

At Gateway One the Building Safety Regulator comments on fire safety matters a planning decision can influence. The response is advice, not a veto, and the timing is what catches developers out.

Read article →
Fire, Structural and Basements7 min read

Article 9A and the fire statement on the application form

Article 9A makes a fire statement a condition of a valid application for relevant high-rise residential buildings. The form is prescribed, the consultee is the Building Safety Regulator, and validation fails without it.

Read article →
Fire, Structural and Basements7 min read

Roof level plant and photovoltaics on a flat roof

Roof plant raises three questions at once: how it reads from above, whether fire can spread across it, and whether anyone can reach it safely. Different people answer each, on different drawings.

Read article →
Fire, Structural and Basements6 min read

Foundations near trees: heave, shrinkage and design depth

On shrinkable clay, a tree 8 metres from your extension can double the foundation depth. The cost arrives at building control stage unless the evidence is gathered early.

Read article →

Not sure which documents your council will ask for?

Enter your postcode and PlanScope recommends the right reports for your project, then drafts them in minutes.

Enter your postcode on PlanScope